SPECIFICATION INDOOR OUTDOOR S 1731 S 1731 Unit Cooling Capacity BTU/h 9,000(4,400-10,600) – Heating Capacity BTU/h 11,000(4,800-12,300) – Moisture Removal L/h 1.6 – phase Single V 230 Hz 50 Power source SIDE VIEW TOP VIEW m/min Cooling ; 7.8 Heating ; 8.6 – Input W Cooling ; 760 Heating ; 860 – Running Current A Cooling ; 3.6 Heating ; 4.1 – Starting Current A 4.
SPECIFICATION INDOOR OUTDOOR S 1731 S 1731 Cross-flow Fan Propeller Fan Induction (4-pole) Induction (6-pole) 18 21 Unit Type Air Circulation Motor Type Rated Output W Plate fin configuration,forced draft Heat Exchanger 18.1FPI 19.5FPI – Capillary Tube – 850(30.
SPECIFICATION INDOOR OUTDOOR S 1735 S 1735 Unit Cooling Capacity BTU/h 11,300(4,800-11,900) – Heating Capacity BTU/h 12,500(4,800-14,300) – Moisture Removal L/h 2.0 – phase Single V 230 Hz 50 Power source SIDE VIEW OUTLET Airflow Method INTAKE Air circulation (at High) Cooling ; Heating ; 3 m/min Cooling ; 970 Heating ; 880 – Running Current A Cooling ; 4.6 Heating ; 4.2 – Starting Current A 4.
SPECIFICATION INDOOR OUTDOOR S 1735 S 1735 Cross-flow Fan Propeller Fan Induction (4-pole) Induction (6-pole) 22 21 Unit Type Air Circulation Motor Type Rated Output W Plate fin configuration,forced draft Heat Exchanger 19.5FPI 19.5 FPI – Capillary Tube – 850(30.
FUNCTIONS REMOTE-CONTROL TRANSMITTER INDOOR UNIT Sensing the room temperature Room temperature sensor (thermistor) ON/OFF Time delay safety control Operation mode selection Restarting is inhibited for approximately 3 minutes. COOL DRY HEAT AUTOMATIC CIRCULATION Indoor fan speed control High, Med, Low Operation indication lamps (LED) Air flow selection POWER AUTOMATIC HIGH MEDIUM LOW (GREEN or RED) Lights up green during operation. Lights up red when negative ions are generated.
FUNCTIONS OUTDOOR UNIT Hot-start control (heating) The indoor fan stops until the evaporator piping temperature will be reached. Anti-freezing control for the evaporator Compressor will be stopped when the evapolator’s piping temperature is below 2℃ for one minute. Compressor will be restarted when the evaporator’s piping temperature is above 2℃.
SERVICE FUNCTION EXPLANATION EMERGENCY AND TEST OPERATION Emergency Operation • • • • Use this operation only when the remote controller is out of order or lost. When the emergency operation switch is pressed, beep starts once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling (or heating when available) according to the room temperature, as follows.
OPERATION DETAILS TIMER OPERATION ON Timer operation • Press the ON/OFF switch. Right after replacing new batteries, set the present time in advance. • Set the “ON Time” : Press the “TIME ADJ” button twice. Adjust the time with the “ , ” button. Press the “TIME ADJ” button twice.The setting of “ON Time” is completed and the present time appears on the LCD. • Set the “ON Timer” : Press the Timer fixing button “ON”. OFF Timer operation • Press the ON/OFF switch.
OPERATION DETAILS TIME DELAY SAFETY CONTROL FUNCTION - FOR PROTECTION OF COMPRESSOR • • Compressor will not restart, in any operation modes, for 3 minutes after its stop. Compressor does not stop during the first ★ 1 seconds of its operation even if the room temperature reaches to the designated temperature, except changing setting temperature.
OPERATION DETAILS DRY MODE OPERATION • • • The compressor will stop when operational frequency reached the minimum frequency and that condition has been kept for ★ 1 seconds and the room temperature becomes 1.3℃ lower than it was set. The compressor will re-start when room temperature becomes 0.7℃ higher than it was set. The operational frequency will be set every ★ 2 seconds of operation.
OPERATION DETAILS HEATING MODE OPERATION • • • The compressor will stop when operational frequency reached the minimum frequency and that condition has been kept for ★ 1 seconds and the room temperature becomes 5.0°C higher than it was set. The compressor will re-start when room temperature becomes 3.0°C higher than it was set. The operational frequency will be set every ★ 2 seconds of operation.
OPERATION DETAILS DEFROSTING OPERATION(FOR OUTDOOR UNIT HEAT EXCHANGER) • • • Defrosting operation is controlled by the temperature of outdoor heat exchanger sensed by the thermistor and the timer switch. Defrosting operation starts when the both of the following conditions are met at the same time. a) 34 minutes’ of continuous run of the compressor after the start of heating operation or after the completion of previous defrosting operation.
OPERATION DETAILS COMPRESSOR STARTING SEQUENCE Max F4 F3 F5 F2 Min 10Hz T1 T2 T3 T(Max) T4 T5 Start Model Frequency F2 F3 Max F4 F5 Min Time T2 T3 T(Max) T4 T5 - 48Hz 58Hz 68Hz - 54Hz 32Hz 1.5min. 1min. 30min. - limitless - 48Hz 58Hz 74Hz - 64.7Hz 32Hz 1.5min. 1min. 40min. - limitless - 48Hz 58Hz 72Hz - 66.7Hz 32Hz 1.5min. 1min. 30min. - limitless - 48Hz 58Hz 80Hz - 69.3Hz 32Hz 1.5min. 1min. 40min.
TROUBLESHOOTING GUIDE FOR YOUR SAFETY USE IN: indoor unit OUT: outdoor unit ● For the safety and proper use and handling of the product, please read and follow the instructions carefully. ● The meaning of the marks below are as follows. Danger Improper use will cause the significant risk of death or serious injury of the user. Warning Improper use may cause the risk of death or serious injury of the user. ● Please refer the marks below.
TROUBLESHOOTING GUIDE INDICATION LAMP Micro computer self-diagnose the points of the troubles and inform it by the combination of the status (On, Flush, or Off) of three lamp indicators on the front panel of the indoor unit.
TROUBLESHOOTING GUIDE CHECK A FOLLOWING STEPS 〔fig. 1〕Voltage of OUT fan motor on the OUT PCB( main) 〔fig. 2〕Continuity of current fuse on the OUT PCB(filter) B : BLACK BR : BROWN W : WHITE B GR R W W R B GR 18 : BLACK : GRAY : RED : WHITE AC230V 10 W BR B AC230V Measure the voltage between white and black in the connector. 〔fig.
TROUBLESHOOTING GUIDE ELECTRIC CHARACTER 〔table 2〕Sensor, temp. defrost Sensor, temp. heat exchanger Sensor, temp. outdoor 〔table 1〕Sensor, temp. room 〔table 3〕Sensor, temp. discharge Temp. (°C) Resistance (k1) Temp. (°C) Resistance (k1) Temp. (°C) Resistance (k1) 10 48 0 31 10 1,130 15 37 5 24 20 660 20 29 10 19 35 320 25 23 15 15 40 250 30 18 20 12 50 160 35 15 25 10 80 50 30 8 35 7 〔table 4〕Sensor, temp. power module Temp.
TROUBLESHOOTING GUIDE WIRING DIAGRAM S 1731 Indoor S 1735 Indoor BL R MOTOR(FAN) BL R TRANSFORMER BL R Y B IONIZER W BR PCB (RECEIVER &DISPLAY) P FUSE (T3.15A) S B MANUAL SWITCH BL SENSOR (TEMP.,ROOM) BL BR B POWER SOURCE SENSOR (TEMP.,HEAT EXCHANGER) B PCB(MAIN) R W MOTOR (LOUVER) BL G/Y EARTH TERMINAL TERMINAL 3 2 1 BLOCK ↓ OUTDOOR UNIT S 1731 Outdoor S 1735 Outdoor COMPRESSOR T R S R W MOTOR (FAN) SENSOR (TEMP., DISCHARGE) SENSOR (TEMP., DEFROST) SENSOR (TEMP.
PERFORMANCE CURVE DIAGRAM REMARKS FOR GAS PRESSURE CHECK AND CHARGING Gas pressure is to be measured at TEST OPERATION for cooling or EMERGENCY OPERATION for heating. (It is operated for 30 minutes at fixed frequency.) If you find substantial diffrence in performance compared with PERFORMANCE CURVE as shown next, recharge the refrigerant.
PERFORMANCE CURVE DIAGRAM S 1731 COOLING (A) 5.0 4.5 4.0 CURRENT 3.5 3.0 2.5 2.0 (°C) 30 25 TEMPERATURE BLOW OUT 20 15 10 5 0 (MPa) 1.5 1.3 SERVICE PORT PRESSURE 1.1 0.9 0.7 0.5 20 25 30 35 (°C) HUMIDITY60% AIR TEMPERATURE INDOOR-OUTDOOR HEATING (A) AIR-TEMPERATURE INDOOR 20°C 5.0 4.5 CURRENT 4.0 3.5 3.0 (°C) 50 45 TEMPERATURE BLOW OUT 40 35 (MPa) 3.5 SERVICE PORT PRESSURE 3.0 2.5 2.
PERFORMANCE CURVE DIAGRAM S 1735 COOLING (A) 5.0 4.5 4.0 CURRENT 3.5 3.0 2.5 2.0 (°C) 30 25 TEMPERATURE BLOW OUT 20 15 10 5 0 (MPa) 1.2 1.1 SERVICE PORT PRESSURE 1.0 0.9 0.8 0.7 20 25 30 35 (°C) HUMIDITY60% AIR TEMPERATURE INDOOR-OUTDOOR HEATING (A) AIR-TEMPERATURE INDOOR 20°C 5.5 5.0 CURRENT 4.5 4.0 3.5 (°C) TEMPERATURE BLOW OUT 50 45 40 35 (MPa) 3.5 SERVICE PORT PRESSURE 3.0 2.5 2.
ELECTRIC CIRCUIT DIAGRAM S 1731 Indoor, S 1735 Indoor INDOOR FAN MOTOR IONIZER YELLOW RED BLUE 1 3 CN7 C1 C3 L1 C2 ZE1 BLACK WHITE BROWN 1 3 5 CN4 RL2A CF1 RL1A PC2B 1 2 3 CN9 THERMISTOR (EVA) THERMISTOR (ROOM) 1 2 3 CN8 4 5 6 7 1 2 3 4 5 6 7 CN1 LOUVER MOTOR RECEIVER UNIT OPERATE LED TIMER LED ELECT LED IONIZER LED PCB(RECEIVER & DISPLAY) PCB(MAIN CONTROLLER) IC1 1 2 CN12 3 4 5 MANUAL SW 1 2 3 4 CN11 RL1B RL2B PC3B CN6 S BLUE 1 3 P RED BLUE PC1A PC2A CN1 1 3 RED TRANSFO
ELECTRIC CIRCUIT DIAGRAM S 1731 Outdoor , S 1735 Outdoor – 23 –
SCHEMATIC DIAGRAM AND PCB’S S 1731 Indoor (Top View) PCB(AC-383) ※ ※ ※ On the PCB a letter of alphabet may be printed in depends on the version. – 24 – .
SCHEMATIC DIAGRAM AND PCB’S S 1735 Indoor (Top View) PCB(AC-382) ※ ※ ※ On the PCB a letter of alphabet may be printed in depends on the version. – 25 – .
SCHEMATIC DIAGRAM AND PCB’S S 1731 Outdoor (Top View) PCB(AC-377) ※ ※ On the PCB a letter of alphabet may be printed in depends on the version. – 26 – .
SCHEMATIC DIAGRAM AND PCB’S S 1735 Outdoor (Top View) PCB(AC-379) ※ ※ On the PCB a letter of alphabet may be printed in depends on the version. – 27 – .
SCHEMATIC DIAGRAM AND PCB’S S 1731 Outdoor, S 1735 Outdoor FILTER PCB(AC-378) ※ ※ On the PCB a letter of alphabet may be printed in depends on the version. – 28 – .
SCHEMATIC DIAGRAM AND PCB’S S 1731 Indoor, S 1735 Indoor (Bottom View) PCB(AC-383, AC-382) S 1731 Indoor, S 1735 Indoor PCB RECEIVER & DISPLAY(AC-359) ※ ※ On the PCB a letter of alphabet may be printed in depends on the version. – 29 – .
SCHEMATIC DIAGRAM AND PCB’S S 1731 Outdoor, S 1735 Outdoor (Bottom View) PCB(AC-377, AC-379) – 30 –
SCHEMATIC DIAGRAM AND PCB’S S 1731 Outdoor, S 1735 Outdoor (Bottom View) FILTER PCB(AC-378) – 31 –
SCHEMATIC DIAGRAM AND PCB’S S 1731 Indoor, S 1735 Indoor SCHEMATIC DIAGRAM(AC-383, AC-382, AC-359) – 32 –
SCHEMATIC DIAGRAM AND PCB’S S 1731 Outdoor, S 1735 Outdoor SCHEMATIC DIAGRAM(AC-377, AC-379) – 33 –
SCHEMATIC DIAGRAM AND PCB’S S 1731 Outdoor, S 1735 Outdoor FILTER PCB(AC-378) – 34 –
PARTS LIST (PCB) S 1731 Indoor, S 1735 Indoor PCB ASSEMBLY(MAIN) AC-382,383 ALTERNATIVE REF. No.
PARTS LIST (PCB) S 1731 Indoor, S 1735 Indoor PCB ASSEMBLY(MAIN) AC-382,383 ALTERNATIVE REF. No.
PARTS LIST (PCB) S 1731 Indoor, S 1735 Indoor PCB ASSEMBLY(RECEIVER&DISPLAY) AC-359 ALTERNATIVE ZP1 REF. No.
PARTS LIST (PCB) S 1731 Outdoor, S 1735 Outdoor PCB ASSEMBLY(MAIN) AC-377, AC-379 ALTERNATIVE OR OR Ref. No. PARTS NAME PARTS No. Q'TY PCB CE-38700 for AC-377 1 PCB CE-38710 for AC-379 1 C1 Film Cap. ECQE2A103D69 1 C10,11 Electrolytic Cap. 25ME47AX+T 2 C105,106,107,108 Ceramic Cap. GRM188B11H331KA01D 4 C12,16 Electrolytic Cap. TC04RKY35VB220MH15F50E0 2 C13 Electrolytic Cap. ESMG500ETC470MF11D 1 C14 Electrolytic Cap. 25ME100HC+T 1 C15,25 Electrolytic Cap.
PARTS LIST (PCB) S 1731 Outdoor, S 1735 Outdoor PCB ASSEMBLY(MAIN) AC-377, AC-379 OR OR D45,46 Diode RB751V-40TE-17 2 DB1 Bridge Diode D15XB60-7009F13 1 DB2 Bridge Diode D15XB60-7001 1 DQ33,34,35 Transistor(BRT Type) DTC143XUAT106 3 DQ36,38 Transistor(BRT Type) DTA114EUAT106 2 HS1 Heat Sink OSH-1625-WFL 1 IC1 Switching Power IC MIP0222SY 1 IC10 Logic IC TC7W00F(TE12L,F) 1 IC11 Comparator IC uPC339G2-E1-A 1 IC12 Shunt Regulator uPC1093T-E1-AZ 1 IC12 Shunt Regulato
PARTS LIST (PCB) S 1731 Outdoor, S 1735 Outdoor PCB ASSEMBLY(MAIN) AC-377, AC-379 OR OR R29,33,36,39 Chip Res. MCR10EZHJ103 4 R30,40,41,46,47,73,99,169 Chip Res. RPC05T223J 8 R31,32 Chip Res. RPC1ST473J 2 R34 Chip Res. RK73B2ATTD100J 1 R35 Chip Res. RK73B2ATTD680J 1 R37 Chip Res. MCR50JZHJ471 1 R4 Cement Res. BPR58CF20LJ 1 R42,89,90,95,96,100,102 Chip Res. RPC05T103J 7 R43 Chip Res. RPC05T184J 1 R44,74,75,147,149,151,152 Chip Res. RPC05T103F 7 R45 Chip Res.
PARTS LIST (PCB) S 1731 Outdoor, S 1735 Outdoor PCB ASSEMBLY(FILTER) AC-378 ALTERNATIVE Ref. No. PARTS NAME PARTS No. Q'TY PCB CE-38800 1 C1,3 Film Cap. ECQU2A105MLA 2 C4,5,6,7,11 Ceramic Cap.
SEMICONDUCTOR LEAD IDENTIFICATION S 1731 Indoor S 1735 Indoor AC-359, AC-382, AC-383 IC1 IC3 M38037M8H-201KP 48 M63823GP 64 1 32 16 9 8 5 17 1 8 1 4 16 IC4 RG1 XC61CN4202NR 1 2 3 4 3 P2 1 S-93LC56ADFJ 33 49 4 IC2 2 S201DH1Y TA78L05 NJM78L05 67 OUT IN NC VSS 23 O G 15 I DQ11∼16 PC3 PC357N9 4 PC2 1 DSK10E S5688G 2 2 3 1 3 1 2 1 GNC 2 IN 3 OUT DB1 ZE1 PD1 TNR10V471K S1ZB60 + ∼ − ∼ SBX1810-52P LD1 PC1 LD2,3 SLR342MG3F SLR342YY3F 9 D1∼3 DTA114EKA DTC1
SEMICONDUCTOR LEAD IDENTIFICATION S 1731 Outdoor S 1735 Outdoor AC-377, AC-378, AC-379 IC1:AC-377,379 IC2:AC-377,379 MIP0222SY IC3:AC-377,379 FSBS15CH60 TMP88CS43 1 64 8 41 65 21 9 40 19 20 10 S C 27 IC5,10:AC-377,379 XC61CN4202NR S-93C76ADFJ TC7W00F 1 2 3 4 3 P2 1 25 1 IC4:AC-377,379 4 80 D 2 OUT IN NC VSS 24 IC6,9:AC-377,379 M63823 HD74HC367 8 4 1 1 9 5 8 16 IC11:AC-377,379 uPC339 IC12:AC-377,379 DB1:AC-377,379 uPC1093T-E1 D15XB60-F13 7 1 8 I G + O ∼ ∼ 14
SEMICONDUCTOR LEAD IDENTIFICATION S 1731 Outdoor S 1735 Outdoor AC-377, AC-378, AC-379 RG1:AC-377,379 NJM7815 uPC78M15 TA78M15 RG2:AC-377,379 D1∼4:AC-377,379 1JU41 TA78L005AP ①I ②O ③G O ③ ①② D31∼38 :AC-377,379 :AC-378 D1,6 D1FL20U S1J G I D42:AC-377,379 D39∼41,44∼46:AC-377,379 DAP202K 1SS355 RB751V ② ② ① ③ D43:AC-377,379 ZD31,32:AC-377,379 U1ZB30 DAN202K DTC143X DTA114E ③ ② ① ③ ① ① ③ ③ T1:AC-377,379 TAEM30M ZE1,2 :AC-377,379 ZE1∼3 :AC-378 TND10SE471K TND10V621K 7 6 ③ DQ33∼36,38:
SEMICONDUCTOR PIN FUNCTION S 1731 Indoor, S 1735 Indoor SEMICONDUCTOR IC1 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Signal Name Function Sensor(Room Temp.) Sensor(Heat Exchanger Temp.) NC A/D Input A/D Input NC Munual Sw. Input Motor(fan) Buzzer Pulse Input (Fan Motor Pulse) NC NC NC NC NC NC NC NC MIN.
SEMICONDUCTOR PIN FUNCTION Fig.1 Fig.2 5V 5V 0V 0V t= 10ms t= 10ms Fig.3 5V 0V t= 20 s R.P.M.
SEMICONDUCTOR PIN FUNCTION S 1731 Outdoor, S 1735 Outdoor SEMICONDUCTOR IC2 PIN FUNCTION Pin No.
SEMICONDUCTOR PIN FUNCTION IC3 PIN FUNCTION Pin No.
THERMISTOR RESISTANCE CHART SENSOR, ROOM TEMPERATURE Indoor Unit SENSOR, ROOM TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 4150±3% STANDARD TEMPERATURE • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • 23kΩ±3% T(°C) -30.0 -29.5 -29.0 -28.5 -28.0 -27.5 -27.0 -26.5 -26.0 -25.5 -25.0 -24.5 -24.0 -23.5 -23.0 -22.5 -22.0 -21.5 -21.0 -20.5 -20.0 -19.5 -19.0 -18.5 -18.0 -17.5 -17.0 -16.5 -16.0 -15.5 -15.0 -14.5 -14.0 -13.5 -13.0 -12.5 -12.0 -11.5 -11.0 -10.
THERMISTOR RESISTANCE CHART Indoor Unit SENSOR, ROOM TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 4150±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 23kΩ±3% T(°C) 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 18.0 18.5 19.0 19.5 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 25.0 25.5 26.0 26.5 27.0 27.5 28.0 28.5 29.0 29.5 30.0 R(kΩ) 48.1 46.9 45.7 44.5 43.4 42.3 41.3 40.2 39.2 38.
THERMISTOR RESISTANCE CHART SENSOR, HEAT EXCHANGER TEMPERATURE Indoor Unit SENSOR, HEAT EXCHANGER TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 3700±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 10kΩ±3% T(°C) -40.0 -39.0 -38.0 -37.0 -36.0 -35.0 -34.0 -33.0 -32.0 -31.0 -30.0 -29.0 -28.0 -27.0 -26.0 -25.0 -24.0 -23.0 -22.0 -21.0 -20.0 -19.0 -18.0 -17.0 -16.0 -15.0 -14.0 -13.0 -12.0 -11.0 -10.0 -9.0 -8.0 -7.0 -6.0 -5.0 -4.
THERMISTOR RESISTANCE CHART Indoor Unit SENSOR, HEAT EXCHANGER TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 3700±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 10kΩ±3% T(°C) 40.0 41.0 42.0 43.0 44.0 45.0 46.0 47.0 48.0 49.0 50.0 51.0 52.0 53.0 54.0 55.0 56.0 57.0 58.0 59.0 60.0 61.0 62.0 63.0 64.0 65.0 66.0 67.0 68.0 69.0 70.0 71.0 72.0 73.0 74.0 75.0 76.0 77.0 78.0 79.0 80.0 R(kΩ) 5.5 5.3 5.1 4.9 4.8 4.6 4.4 4.3 4.1 4.
THERMISTOR RESISTANCE CHART SENSOR, DEFROST TEMPERATURE Outdoor Unit SENSOR, DEFROST TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 3700±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 10kΩ±3% T(°C) -40.0 -39.0 -38.0 -37.0 -36.0 -35.0 -34.0 -33.0 -32.0 -31.0 -30.0 -29.0 -28.0 -27.0 -26.0 -25.0 -24.0 -23.0 -22.0 -21.0 -20.0 -19.0 -18.0 -17.0 -16.0 -15.0 -14.0 -13.0 -12.0 -11.0 -10.0 -9.0 -8.0 -7.0 -6.0 -5.0 -4.0 -3.0 -2.0 -1.
THERMISTOR RESISTANCE CHART Outdoor Unit SENSOR, DEFROST TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 3700±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 10kΩ±3% T(°C) 40.0 41.0 42.0 43.0 44.0 45.0 46.0 47.0 48.0 49.0 50.0 51.0 52.0 53.0 54.0 55.0 56.0 57.0 58.0 59.0 60.0 61.0 62.0 63.0 64.0 65.0 66.0 67.0 68.0 69.0 70.0 71.0 72.0 73.0 74.0 75.0 76.0 77.0 78.0 79.0 80.0 R(kΩ) 5.5 5.3 5.1 4.9 4.8 4.6 4.4 4.3 4.1 4.0 3.8 3.
THERMISTOR RESISTANCE CHART SENSOR, DISCHARGE TEMPERATURE Outdoor Unit SENSOR, DISCHARGE TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 4250±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 80.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 50kΩ±3% T(°C) -40.0 -39.0 -38.0 -37.0 -36.0 -35.0 -34.0 -33.0 -32.0 -31.0 -30.0 -29.0 -28.0 -27.0 -26.0 -25.0 -24.0 -23.0 -22.0 -21.0 -20.0 -19.0 -18.0 -17.0 -16.0 -15.0 -14.0 -13.0 -12.0 -11.0 -10.0 -9.0 -8.0 -7.0 -6.0 -5.0 -4.0 -3.0 -2.
THERMISTOR RESISTANCE CHART Outdoor Unit SENSOR, DISCHARGE TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 4250±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 80.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 50kΩ±3% T(°C) 40.0 41.0 42.0 43.0 44.0 45.0 46.0 47.0 48.0 49.0 50.0 51.0 52.0 53.0 54.0 55.0 56.0 57.0 58.0 59.0 60.0 61.0 62.0 63.0 64.0 65.0 66.0 67.0 68.0 69.0 70.0 71.0 72.0 73.0 74.0 75.0 76.0 77.0 78.0 79.0 80.0 R(kΩ) 250.4 239.3 228.8 218.8 209.3 200.2 191.
THERMISTOR RESISTANCE CHART SENSOR, OUTDOOR TEMPERATURE Outdoor Unit SENSOR, OUTDOOR TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 3700±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 10kΩ±3% T(°C) -40.0 -39.0 -38.0 -37.0 -36.0 -35.0 -34.0 -33.0 -32.0 -31.0 -30.0 -29.0 -28.0 -27.0 -26.0 -25.0 -24.0 -23.0 -22.0 -21.0 -20.0 -19.0 -18.0 -17.0 -16.0 -15.0 -14.0 -13.0 -12.0 -11.0 -10.0 -9.0 -8.0 -7.0 -6.0 -5.0 -4.0 -3.0 -2.0 -1.
THERMISTOR RESISTANCE CHART Outdoor Unit SENSOR, OUTDOOR TEMPERATURE B CONSTANT • • • • • • • • • • • • • • • • • • • • • • • • 3700±3% STANDARD TEMPERATURE • • • • • • • • • • • • • 25.0°C STANDARD RESISTANCE • • • • • • • • • • • • • • • 10kΩ±3% T(°C) 40.0 41.0 42.0 43.0 44.0 45.0 46.0 47.0 48.0 49.0 50.0 51.0 52.0 53.0 54.0 55.0 56.0 57.0 58.0 59.0 60.0 61.0 62.0 63.0 64.0 65.0 66.0 67.0 68.0 69.0 70.0 71.0 72.0 73.0 74.0 75.0 76.0 77.0 78.0 79.0 80.0 R(kΩ) 5.5 5.3 5.1 4.9 4.8 4.6 4.4 4.3 4.1 4.0 3.8 3.
EXPLODED VIEW (INDOOR UNIT) S 1731 Indoor accessories 26 25 11 27 22 30 28 15 29 20 23 14 30 24 9 13 1 4 6 5 21 2 12 3 10 7 8 19 16 31 18 17 – 59 –
EXPLODED VIEW (INDOOR UNIT) S 1735 Indoor 21 25 24 26 30 28 27 22 14 13 10 23 8 12 19 6 4 5 1 2 3 11 26 7 20 18 15 20 29 17 9 – 60 – 16
EXPLODED VIEW (OUTDOOR UNIT) S 1731 Outdoor S 1735 Outdoor 11 6 1 9 14 22 10 13 18 23 25 29 5 19 12 3 15 28 2 26 8 20 21 24 30 7 4 17 accessories 16 27 – 61 – 31
PARTS LIST (INDOOR UNIT) NO. S 1731 Indoor 1 CONTROLLER ASSY. 20446670 2 PCB (MAIN) 30066610 3 PCB (RECEIVER & DISPLAY) 30055510 30013610 4 SENSOR (TEMP,ROOM & HEAT EXCHAGER) 5 30055070 30054290 30021680 6 TRANSFORMER 51955370 30055520 7 TERMINAL BLOCK 51620840 8 CORD,POWER SUPPLY 30021550 9 FRONT PANEL 20088190 10 INLET GRILLE 20431521 11 REAR CASE ASSY.
PARTS LIST (INDOOR UNIT) NO. PARTS NAME S 1735 Indoor 1 CONTROLLER ASSY. 20446680 2 PCB (MAIN) 30066620 3 PCB (RECEIVER & DISPLAY) 30055510 30013610 4 SENSOR (TEMP,ROOM & HEAT EXCHAGER) 5 30055070 30054290 6 TERMINAL BLOCK 51620840 7 CORD,POWER SUPPLY 30021550 8 FRONT PANEL ASSY. 20088200 9 INLET GRILLE 20431521 10 REAR CASE ASSY. 20048710 11 WIRING LID 20044490 12 MOTOR,FAN 53501610 30063710 50810090 13 TANGENTIAL FAN 50810060 50810080 14 BEARING ASSY.
PARTS LIST (OUTDOOR UNIT) NO. PARTS NAME S 1731 Outdoor S 1735 Outdoor 1 TOP PANEL ASSY. 20444970 ← 2 FRONT PANEL 20413612 ← 3 COMPRESSOR 30061680 ← 4 BOTTOM PANEL ASSY. 20445011 ← 5 RIGHT SIDE PANEL ASSY. 20415191 ← 6 LEFT SIDE PANEL ASSY. 20415201 ← 7 VIBRATION PROOF RUBBER (comp.) 30061700 ← 8 VALVE COVER 20130230 ← 9 BAFFLE PANEL ASSY. 20447540 ← ← 10 REACTOR 30055560 11 CONDENSER ASSY.
RA-42-[1] ISSUED DEC.