SRE 240 E / SRE 246 E 3 MANUEL D'UTILISATION 2 2 GEBRAUCHSANWEISUNG 10 6 BRUGSANVISNING 20 5 INSTRUCCIONES DE USO 30 FIN KÄYTTÖOHJE 40 4 OPERATING MANUAL 50 > ISTRUZIONI D’USO 60 u BRUKSANVISNING 70 1 GEBRUIKSAANWIJZING 80 = BRUKSANVISNING 90
AFAQ AFNOR CERTIFICATION 11, AVENUE FRANCIS DE PRESSENSE 93571 SAINT-DENIS LA PLAINE CEDEX FICHE INFORMATIVE La marque NF garantit la qualité de cet article suivant les normes françaises et Règles de certification de l’application NF 128 CHAUFFAGES MOBILES A COMBUSTIBLE LIQUIDE NF 128 02 / 02 CONFORME A LA NORME NF D 35-300 ET AUX SPECIFICATIONS COMPLEMENTAIRES DEFINIES PAR LES REGLES DE CERTIFICATION DE L’APPLICATION NF 128 PRINCIPALES CARACTERISTIQUES CERTIFIEES: • Sécurité du dispositif d’allumage •
Dear Sir, Madam, Congratulations with your purchase of the Zibro, the number one brand among movable heaters. You have purchased a first-class quality product, which will serve you for many years to come. This, of course, provided you use the heater correctly. Please read these Directions for Use first, to ensure maximum lifetime for your Zibro. Your heater comes with a 48-month manufacturer’s warranty on all defects in material or workmanship. We wish you much warmth and comfort with your Zibro.
GENERAL DIRECTIONS FOR USE MAIN COMPONENTS Below you will find the main steps to be taken for using your Zibro. For more details, please refer to the A Front plate B Grid C Base plate 4 Lid for removable tank E Operation panel F Handle G Removable tank H Air filter I Vent filter J Thermostat K Plug + cord L Information display MANUAL (pages 53 ff.). 1 Remove all packaging materials (Fig. A). 2 Fill the removable tank 7 (refer to Section B, Fig. D).
WHAT YOU NEED TO KNOW IN ADVANCE ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION This heater is equipped with an air quality control system . When there is insufficient ventilation in the room or when the heater is being used in a room which is too small, the heater will shut off automatically. For comfortable and safe heating ensure that there is sufficient ventilation. Note: To avoid unexpected shut off, we recommend to put a door or window ajar when the heater is operating.
MANUAL A E E E E INSTALLING THE HEATER 1 Carefully remove your Zibro from the box and check the contents. In addition to the heater you also need to have: E a manual fuel pump E a transportation cap E these directions for use Keep the box and the packaging materials (Fig. A) for storage and/or transportation. 2 Open the lid of the removable tank D and remove the piece of cardboard. 3 Fill the removable tank as indicated in Section B. 4 The floor should be firm and completely level.
Let the remaining fuel in the pump flow back into the jerrycan and carefully remove the pump. Carefully screw the fuel cap back on the tank. Clean off any spilled fuel. 8 Check whether the fuel cap is straight and tightened properly. Reinstall the removable tank in the heater (cap down). Close the lid. C SETTING THE CLOCK It is only possible to set the correct time, when the heater is connected to the mains and not burning. Use the adjustment keys O to set the time.
1 Press the button M and then the TIMER key P immediately after that. The TIMER light and the information display L will start blinking. 2 Use the adjustment keys O to set the time at which the heater must ignite. Use the key ( hour) to set the hours and the key ( min.) to set the minutes (interval of 5 minutes). N H: The TIMER indicator light indicates that the timer function has been switched on.
(SRE240E) The heater has been in operation (SRE246E) continuously for a period of 69/50 hours and has turned itself off automatically. + Out of fuel. -- -- : -- : -- + e-11+ hours Switch the heater back on. Refill removable tank. Too little ventilation. Ventilate better. Too little ventilation. Ventilate better. Always contact your Zibro dealer for any malfunctioning not listed above.
J THE CORRECT USE OF 'SAVE' The 'SAVE' function allows you to limit the temperature. When this function is activated, the heater will automatically switch off, when the room temperature exceeds the set temperature by 3°C. Subsequently, when the room temperature has dropped again to the set temperature, the heater will automatically switch on again. Activate the 'SAVE' setting by pressing the appropriate Q key.
1 Remove the removable tank 7 from the heater and remove the fuel filter (Fig. N). Some drops may leak from the filter; keep a cloth at hand. Fuel filter 2 Remove the dirt by tapping the fuel filter upside-down against a hard surface. (Never clean it with water!) N 3 Reinstall the fuel filter into the heater. We recommend that you remove dust and stains in time with a damp cloth, because otherwise these may cause stains that are hard to remove. ☞ N Do not remove any heater components yourself.
Q WARRANTY PROVISIONS Your heater comes with a 48-month warranty starting on the date of purchase. Within this period all defects in material or workmanship will be repaired without any charge. The following provisions shall apply regarding this warranty: 1 We expressly dismiss all other claims for damages, including consequential damages. 2 Any repairs or replacements of components within the term of warranty will not result in an extension of the term of warranty.
G D E F A J T B I H C K L R N QP E E E E E E E E E E O S E E E E E E M E E E E E E E E E E
i ÖSTERREICH PVG Austria VertriebsgmbH Salaberg 49 3350 HAAG tel: +43 7434 44867 fax: +43 7434 44868 email: pvgaustria@zibro.com 4 UNITED KINGDOM Scott Brothers Ltd. The Old Barn, Holly House Estate Cranage, Middlewich, CW10 9LT UK tel.: +44 1606 837787 fax: +44 1606 837757 email: sales@scottmail.co.uk e BELGIË PVG Belgium NV/SA Industrielaan 55 2900 SCHOTEN tel: +32 3 326 39 39 fax: +32 3 326 26 39 email: pvgbelgium@zibro.