Operation Manual

transportation cap
+
O
2
Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(Never clean it with water!)
3
Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains in time with a damp cloth,
because otherwise these may cause stains that are hard to remove.
Do not remove any heater components yourself. Always contact your Zibro
dealer for repairs. When the power cord is damaged, it may only be replaced
by an authorised fitter. Use a new cord of the type H05 VV-F.
N STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local regu-
lations for the disposal of domestic chemical waste. Always start the new heating
season with fresh fuel. When you start re-using the heater follow the instructions
again (starting from section A and as specified).
O TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
1
Let the heater cool down.
2
Remove the removable tank from the heater and remove the fuel filter
(refer to Section M, Fig. N). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
3
Place the transportation cap into the position of the fuel filter (Fig. O). Press it
tight. The transportation cap will, as much as possible, prevent oil leakage
from the heater during transport.
4
Always move the heater in an upright position.
5
Make the fixed tank empty with a fuel pump before transportation or in case
of wrong or dirty fuel. First remove the fuel filter and then insert the fuel
pump into the empty fixed tank. Follow the same procedure if the fuel tank
contains water.
P SPECIFICATIONS
Ignition electrical Dimensions (mm) width 435
Fuel paraffin (including base plate) depth 315
Capacity (kW) max. 3.50 height 437
Capacity (kW) min. 1.05 Accessories manual fuel pump
Suitable space (m
3
)
**
54-150 transportation cap
Fuel consumption (l/hr)
*
0.365 Mains 230V
Fuel consumption (g/hr)
*
292 -- AC/50 Hz
Burning time per tank (hr)
*
20.8
Electrical consumption
igniter 320 W
Capacity removable tank (litres) 7.6 continuous 24 W
Weight (kg) 11.5 Fuse rating 250V, 5A
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
2
level (NDIR CO
2
-sensor E-Guard ).
* At maximum setting ** Specified values are indicative