User's Manual

Zinwave 2700 DAS – User Manual
Issue 1.2
April 2007
© Zinwave Ltd. 2007
Chapter 2
Quick Start
2.1 Overview
This chapter provides a brief overview over the steps required to setup a Zinwave
2700 DAS. For a more detailed description of each step please refer to the relevant
section of this user guide.
2.2 Setting up the Hub Unit
2.2.1 Mount the Hub
o Mount the HU in a 19” equipment rack using the provided
rack-mounting brackets and screws. Alternatively the HU
can be shelf-mounted using the provided rubber feet.
section 3.1.4.1
2.2.2 Connect the Hub
2.2.2.1 RF
o Connect up to four RF signal sources (BTS, BDA,
repeater, or WLAN access point) to the RF ports located
on the back of the HU. Each RF port has two simplex
SMA-female connectors, one for downlink and one for
uplink. When connecting an RF signal source equipped
with a duplex connector, a diplexer or circulator is required
to separate uplink and downlink signals. When setting up a
larger system consisting of several basic 2700 DAS, a
splitter is required to feed the RF signals into each HU.
section 3.1.4.4
2.2.2.2 Power and Control
o Make sure that the ON/OFF switch is in the OFF (O)
position. Connect the AC power cord to the HU. Plug the
AC power cord into an outlet providing AC power (110-230
V, 50-60 Hz).
section 3.1.4.2
o For local control connect an RS232 null-modem from a
computer running a RS232 terminal (e.g. Microsoft
section 3.1.4.3