60 Hz). A green LED on the PoE adaptor will illuminate.
o Connect the PoE adaptor (the port labeled “To
Equipment”) to the RJ45 connector on the AU using a
Cat5 Ethernet cable no longer than 100m. On powering up
the green LED indicators on the RJ45 connector will
illuminate.
o 2760 only: Alternatively the AU can be powered using the
optional 48V mains adaptor. Do not connect both types of
power adaptors to the AU at the same time as this may
cause permanent damage to the unit.
2.3.3.3 Optical Fiber
section 3.4.4.4
o 2760 AU only: Insert the SFP module into the SFP port on
the AU. Push the module firmly into the SFP port to ensure
that it is fully latched.
o Connect the Zinwave fiber-optic patch-lead from the patch-
panel of your fiber distribution to the SFP, making sure that
both sides of the duplex connector are fully latched. The
connector labeled “Equipment” connects to the HU, the
connector labeled “Infrastructure” connects to the fiber
distribution.
o When using MMF, ensure that the patch-leads are of the
same MMF type (i.e. OM1, OM2 or OM3) as your fiber
infrastructure
2.4 Configuring the system
2.4.1 Configure the network interface of the HU
o Connect to the HU through the RS232 interface using the
following settings for the serial port:
19200 Baud, 8 Data Bits, 1 Stop Bit, No Parity and no
flow control.
section 4.3.1
o If the default network interface settings do not match your
network configuration, change the IP address, the subnet
mask and the gateway address of the network port using
the following command line interface (CLI) commands.
Each command is terminated by a carriage return.
config ip <xxx.xxx.xxx.xxx>
config netmask <xxx.xxx.xxx.xxx>
config gateway <xxx.xxx.xxx.xxx>
section 4.3.3.2
section 4.3.4.1
o Reboot the HU using the following CLI command:
reboot
2.4.2 Install the ZinConfig utility tool
o Place the installation CD in your CD drive. If the installer
does not start automatically, open a Windows File Explorer
window, and double-click on readme.htm
section 4.2.1