User's Manual

Zinwave 2700 DAS – User Manual
Issue 1.2
April 2007
© Zinwave Ltd. 2007
System Status LED Indicates the status of the 2700 DAS
(see
Table 3-2)
SFP ports and LED indicators
SFP port
8 SFP ports which can be individually
populated with the Zinwave 2780 SFP module.
SFP Fault LED indicates a fault in the fiber-
optic link or a fault
in the attached AU (see Table 3-3)
SFP Status LED Indicates the status of the SFP port (see
Table
3-3)
RF ports
RF Uplink 4 simplex SMA-female connectors (
labeled 1 to
4) located at the rear of the HU to connect to
the RX port of a radio TXR.
RF Downlink 4 simplex SMA-female connectors (
labeled 1 to
4) located at the rear of the HU to connect to
the TX port of a radio TRX.
Control and Power
Reset switch
Can be used to reset the HU to the factory
default state (refer to Table 4-4
for a list of all
default settings)
RJ45 Ethernet port Connects t
o a local area network (LAN) for
remote control and management of the system
9-pin sub-D
connector
For local control of the system
via a RS232
null-modem cable.
Mains input
connector
IEC connector to mains (110-240V, 50-
60)
including fuse tray for 2 × 2A fuses
ON/OFF switch (O) indicates OFF state, (I) indicates ON state
Table 3-2 lists the possible indications of the Hub and system LEDs. A description of
the SFP port indicators on is provided in Table 3-3.
Table 3-2: Description of Hub + System LED indicators.
LED indicators Description
No power to unit
Unit operational
Fault (see section 5.1.1)
Power
Fault
System
Power
Fault
System
Power
Fault
System