User's Manual

Zinwave 2700 DAS – User Manual
Issue 1.2
April 2007
© Zinwave Ltd. 2007
3.2.3 Ports
3.2.3.1 Electrical port
The electrical connection of the SFP is via a push-fit 20-pin connector located at the
rear of the module.
3.2.3.2 Optical port
The optical port on the SFP module is LC duplex (according to IEC 61754-20).
Looking from the front, the optical transmit port is on the left hand side and the optical
receive port is on the right hand side.
WARNING
Optical emission can damage your eye-sight. DO NOT look directly into the transmit
port of an active SFP module.
3.2.4 Installation
The SFP is a hot pluggable module. To install the SFP in the HU or the AU, the unit
does NOT need to be powered down. The remaining system remains completely
operational and unaffected by plugging or un-plugging a module into an SFP port.
To insert the SFP, hold the
module by the metal body and
slide it into the designated HU/AU
port. An audible click can be
heard when the SFP is fully
latched. Ensure that the de-latch
bail is in the upright position (this
prevents accidental unlatching of
the module).
Figure 3-9: Picture of fully latched SFP module.
Removal of the SFP is achieved
by extending the de-latch bail and
pulling it away from the unit.
Figure 3-10: To remove the SFP pull at the de-latch bail.