o Using an external 48VDC power supply unit (optional).
Mount the PSU next to the Antenna Unit using the provided brackets with
the IEC mains connector facing downwards
Connect the mains cable from the PSU to an outlet providing 110 250 V,
50 – 60 Hz AC power.
Connect the DC cable of the PSU to the 2-pin latching input of the Antenna
Unit
o By Power over Ethernet. (PoE) using an IEEE802.3af compliant PoE injector.
Using the IEEE 802.3af PoE protocol the PoE injector can be connected to
the Antenna Unit with a Cat5 Ethernet cable of up to 100 m length. This can
be beneficial in situations where it is difficult to provide AC power near the
Antenna Unit location
Install the PSU in a suited location, making sure that adequate air circulation
is provided.
Connect the Cat5 Ethernet cable to the connector labeled “To Network Jack
on the PoE injector.
Connect the other end of the Ethernet cable to the RJ45 connector on the
Antenna Unit.
CAUTION
Connecting more than one source of power at a time to any single 2760 AU can
cause permanent damage to the unit.
Figure 3-20: Connecting the DC supply unit or the PoE mains adaptor.
Table 3-11: DC Power Supply Unit (PSU) characteristics.
Parameter Min Typical Max Unit Comment
Power supply voltage 40 48 V
Power supply frequency DC -
Power consumption 3 W
3.3.5 Environmental
Table 3-12: Environmental specifications of 2760 + 2765 Antenna Unit.