4.2.8 Status and Alarms
When an alarm is present, the SFP port
or the status box in the AU frame is
colored red. Status and alarm
information is displayed by left-clicking
on one of the colored boxes.
Alternatively status information on the
SFP ports can be displayed by right-
clicking on the SFP port and selecting
“Alarms from the pop-up menu (Figure
4-7).
Clicking on one of the SFP ports displays
information on the HU SFP. Clicking on
the colored box in the AU frame displays
information on the AU optical transceiver
Figure 4-7: Reading out alarms on the optical link.
A box will appear describing the
alarm if present together with a
range of status information
(Figure 4-8). The displayed
parameters are:
o RX optical power
o TX optical power
o Laser bias current
o SFP supply voltage
o SFP temperature
Figure 4-8: Alarm description.
4.3 Control via Command Line Interface (CLI)
A detailed description of the full CLI functionality can be found in Zinwave 2700 DAS –
Software Manual.
The CLI can be accessed directly with an RS-232 serial connection, or remotely
through a network using the Telnet protocol.