Figure 4-9: Required connections for local and remote control of the 2700 DAS.
4.3.1 Connecting to the CLI via RS232
This section describes how to access the CLI via the RS232 protocol using the
Microsoft Windows based HyperTerminal application. The setup using a different
terminal emulation application is likely to be very similar.
The serial port on the HU is configured as DTE (Data Terminal Equipment). When the
HU is directly connected to the serial port of a computer (which is another DTE), a null
modem has to be used. Follow these steps to establish a RS232 connection:
o Connect your laptop/PC via the null modem cable to the hub unit.
o Run HyperTerminal. This
application can be found
under Start
All Programs
Accessories
Communications
HyperTerminal. After
entering a descriptive name
for the connection click OK
to proceed.
Figure 4-10 Open a new HyperTerminal session.
Serial
Ethernet
HU
COM port
9-pin sub-D
null-modem cable
Ethernet
Cable
Ethernet