Installation and Operating Instructions

Page 2 of 8 804984 - SP_Zip Filter MicroPurity - 06.18 v1.02
Designed for indoor use only – do not expose filters to the elements of nature.
Do not install where exposed to direct sunlight or temperatures <4°C or >40°C.
Must be installed with service isolating valve and double non-return valve.
Minimum safe operating water pressure is 70 kPa, maximum 700 kPa.
Must be installed with pressure reduction valve if pressure exceeds 700 kPa.
Do not install where water quality is unknown or microbiologically unsafe.
After a period of non-use thoroughly flush the filter or tanks.
For safety’s sake, replace all filter cartridges at intervals of 12 months or less.
Replace any filter if water flow slows or if unpleasant tastes or odours occur.
WARNING
To reduce the risk associated with the ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. Systems certied for cyst reduction
may be used on disinfected water that may contain lterable cysts. EPA Establish-
ment 070595-MEX-001
To reduce the risk associated with hazardous voltage due to an installer drilling through
existing electric wiring or water pipes in the area of installation:
Do not install near electric wiring or piping which may be in path of a drilling tool
when selecting the position to mount the system bracket.
CAUTION
To reduce the risk associated with property damage due to water leakage:
Read and follow Use Instructions before installation and use of this system.
Installation and use MUST comply with all state and local plumbing codes.
Protect from freezing, remove lter cartridge when temperatures are expected to
drop below 4.4°C.
Do not install systems in areas where ambient temperatures may go above 43° C.
Do not install on hot water supply lines. The maximum operating water temperature
of this system is 38°C.
If water pressure exceeds 700 kPa, you must install a pressure limiting valve. Con-
tact a plumbing professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer condi-
tions exist you must install a water hammer arrester. Contact a plumbing profes-
sional if you are uncertain how to check for this condition.
Where a backow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
Do not use a gas torch or other high temperature sources near system, cartridges,
plastic ttings or plastic plumbing.
Do not install in direct sunlight or outdoors.
When selecting the position to mount the bracket do not install near water pipes
which will be in path of a drilling tool.
Mount system in such a position as to prevent it from being struck by other items
used in the area of installation.
Ensure that the location and fasteners will support the weight of the system when
installed and full of water.
Ensure all tubing and ttings are secure and free of leaks.
Do not install using rigid piping. System intended for use with plastic water lines
(such as PEX tubing, PE tubing, PP tubing).
The disposable lter cartridge MUST be replaced every 12 months, at the rated
capacity or sooner if a noticeable reduction in ow rate occurs.
Read These Warnings First