Installation and Operating Instructions

Page 6 of 8 804984 - SP_Zip Filter MicroPurity - 06.18 v1.02
Filter Performance Data - 3 Micron
* The term “bacteriostatic” indicates that the system
limits the passage or growth of bacteria that may
already exist in the incoming water. It does not mean
that water leaving the system is safer to drink than
water entering the system.
It is essential that the manufacture’s recommended installation, maintenance and filter replacement requirements be carried out for the
product to perform as advertised. See installation Manual for details.
Note: While the testing was performed under standard laboratory conditions, actual performance may vary.
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 for the reduction of
the substances listed below. The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L
4 mg/L /
5 mg/L
50% 0.05 mg/L 90.6%
Particulate Class II
particles 1 to <5μm
at least 10,000
particles / mL
85% 97.1%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
*Tested using flow rate = 1.0 gpm; pressure = 60 ± 3 psig; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
United States Environmental Protection Agency (USEPA) Safe Drinking Water Act /
New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1.5Z3S, ZENITH 1.5NZ3S, BIRKO 1.5B3S, ZIP 2Z3S,
ZENITH 2NZ3S
System Tested and Certified by NSF International
against NSF/ANSI Standard 42 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Filtration
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class II
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
I Microbiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria.
N/A
II (b) Virus Removal Will remove or inactivate virus.
N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless
II(a) and II(b) are passed.
N/A
III Particulate Reduction Reduces cloudiness.
N/A
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
Lead
N/A
Legend: = Pass N/A = Not Applicable
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
Install vertically with cartridge hanging down
Use minimum length of tubing possible
Flush to drain for 5 minutes at full flow
Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually
For cold water use only.
Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
Pressure requirement: 10 -125 psi (0.7 - 8.6 bar),
non-shock
Temperature: 35 -100°F (2-38°C)
MODEL Flow Rate (Lpm) Capacity
1.5Z3-S 3.75 Lpm 13248 L
2Z3-S 5.678 Lpm 17034 L
1.5NZ3-S 3.75 Lpm 13248 L
2NZ3-S 5.678 Lpm 17034 L
1.5B3-S 3.75 Lpm 13248 L
SPECIAL NOTICES
Installation instructions, parts and service availability, and
standard warranty are included with the product when
shipped.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe, or
of unknown quality without adequate disinfection before or
after the system.
The contaminants or other substances removed or reduced
by this water treatment system are not necessarily in your
water.
Check for compliance with state and local laws
and regulations.
Tested under standard laboratory conditions as
specified above. Actual performance may vary
depending on influent water conditions.
The term "bacteriostatic" indicates that the system limits
the passage or growth of bacteria that may already exist in
the incoming water. It does not mean that water leaving the
system is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350051
Global-Mark.com.au
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L
4 mg/L /
5 mg/L
50% 0.05 mg/L 97.4%
Particulate Class I
particles 0.5 to <5μm
at least 10,000
particles / mL
6,433,333/L 85% 47,388/L 99.3%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 HEALTH EFFECTS
Cyst Minimum 50,000 / L
99.9% /
<1/100 L
99.95% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.155 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L 0.001 mg/L 98.9%
Lead 6.5 0.15 mg/L ± 10% 0.147 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L 0.0005 mg/L 99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1ZLS, ZENITH 1NZLS, BIRKO 1.5BLS, ZIP 1.5ZLS,
ZENITH 1.5NZLS, ZIP 2ZLS, ZENITH 2NZLS, INSTANTA 1.5INLS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
I Microbiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria.
N/A
II (b) Virus Removal Will remove or inactivate virus.
N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III Particulate Reduction Reduces cloudiness.
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
Lead
Legend: = Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush to drain for five (5) minutes at full flow.
Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
For cold water use only.
Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
Temperature: 35 -100°F (2-38°C)
Model Flow Rate Capacity
1Z-LS 3.75 Lpm 4163 L
1.5Z-LS 5.678 Lpm 6813 L
2Z-LS 5.678 Lpm 9463 L
1NZ-LS 3.75 Lpm 4163 L
Model Flow Rate Capacity
1.5NZ-LS 5.678 Lpm 6813 L
2NZ-LS 5.678 Lpm 9463 L
1.5B-LS 5.678 Lpm 6813 L
1.5IN-LS 5.678 Lpm 6813 L
SPECIAL NOTICES
Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350001
Global-Mark.com.au
OPERATING SPECIFICATIONS
Pressure requirement: 10 -125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35 -100°F (2-38°C)
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI *
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specied in NSF/ANSI Standard 42.
System Tested and Certied by NSF International
against NSF/ANSI Standard 42 for the reduction of:
STANDARD NO.42 -
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Filtration
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class II
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 for the reduction of
the substances listed below. The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 42.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 AESTHETIC EFFECTS
Chlorine 2.0 mg/L ± 10% 2 mg/L
4 mg/L /
5 mg/L
50% 0.05 mg/L 90.6%
Particulate Class II
particles 1 to <5μm
at least 10,000
particles / mL
85% 97.1%
Bacteriostatic Unit passes NSF Std. 42 for Bacteriostatic effects.
*Tested using flow rate = 1.0 gpm; pressure = 60 ± 3 psig; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
United States Environmental Protection Agency (USEPA) Safe Drinking Water Act /
New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1.5Z3S, ZENITH 1.5NZ3S, BIRKO 1.5B3S, ZIP 2Z3S,
ZENITH 2NZ3S
System Tested and Certified by NSF International
against NSF/ANSI Standard 42 for the reduction of:
STANDARD NO. 42
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Filtration
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class II
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class Treatment Type Function Pass
I Microbiological Status
Bacteriostatic Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria.
N/A
II (b) Virus Removal Will remove or inactivate virus.
N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia
.
Will not remove or inactivate bacteria
unless
II(a) and II(b) are passed.
N/A
III Particulate Reduction Reduces cloudiness.
N/A
IV Taste and Odour Reduction Reduces tastes and odours.
V Chemical Treatment Decreases certain chemicals:
– Lead
N/A
Legend: = Pass N/A = Not Applicable
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
Install vertically with cartridge hanging down
Use minimum length of tubing possible
Flush to drain for 5 minutes at full flow
Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually
For cold water use only.
Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
Pressure requirement: 10 -125 psi (0.7 - 8.6 bar),
non-shock
Temperature: 35 -100°F (2-38°C)
MODEL Flow Rate (Lpm) Capacity
1.5Z3-S 3.75 Lpm 13248 L
2Z3-S 5.678 Lpm 17034 L
1.5NZ3-S 3.75 Lpm 13248 L
2NZ3-S 5.678 Lpm 17034 L
1.5B3-S 3.75 Lpm 13248 L
SPECIAL NOTICES
Installation instructions, parts and service availability, and
standard warranty are included with the product when
shipped.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe, or
of unknown quality without adequate disinfection before or
after the system.
The contaminants or other substances removed or reduced
by this water treatment system are not necessarily in your
water.
Check for compliance with state and local laws
and regulations.
Tested under standard laboratory conditions as
specified above. Actual performance may vary
depending on influent water conditions.
The term "bacteriostatic" indicates that the system limits
the passage or growth of bacteria that may already exist in
the incoming water. It does not mean that water leaving the
system is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350051
Global-Mark.com.au
AS/NZS 3497
WM -0350001
Global-Mark.com.au
Model Flow Rate Capacity Kit #
3mic MicroPurity lter 1.5S 3.75 Lpm 13248 L 93703
3mic MicroPurity Filter 2S 5.678 Lpm 17034 L 93705