Quick Guide

Quick Start Installation Guide
807118 v1.00 01.21 G5 BC Quick Start Guide
9
SECTION 4: Technical data
A pressure limiting valve must be fitted for mains water pressures
above the maximum limits stated above in accordance with local
plumbing regulations.
Note: All models (excluding UK) have an internal pressure limiting device
to reduce the maximum mains regulated pressure (700kPa in Australia),
protecting the system against pressure surges above 500kPa.
!
Water supply connection
1/2” BSP (G1/2).
Booster specification
Specification Rating
Nominal power 2.2kW
Nominal current 10A
Flow rate 1.2 L/m
Water supply pressure requirements
Component
Min - Max pressure, kPA (bar)
Australia UK
HydroTap 170 (1.7) - 700 (7.0) 170 (1.7) - 500 (5.0)
Vented Mixer Tap 300 (3.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Booster 200 (2.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Limescale filter 200 (2.0) - 700 (7.0) 200 (2.0) - 500 (5.0)