Owner`s manual
For a programmed event to
occur, the event must be
programmed at least 1 minute
in the future. If you return to
Run Mode after the start of a
programmed event, that event
will not occur until the next
programmed interval.
For D-Cell Battery Power Versions
1. Check for 6.0 volts DC or greater coming from the battery
holder. If voltage is absent, replace the batteries. If voltage is
present, proceed with step 2.
2. Check for 4.5 volts DC or greater at the motor connection wires
with the motor disconnected and the pump Prime button
activated. If this voltage is present, replace the motor gearbox.
If the voltage is absent, replace the main PCB.
Pump Will Not Run
1. Check that the squeeze tube or pump cartridge is not jammed.
2. Check the chemical uptake line for kinks.
3. Verify that the chemical uptake line is not forming a seal against the
side or bottom of the chemical drum (See Installing Supply Lines in
Installation).
4. Check to see that the motor connection wires are properly connected
from the main PCB to the motor gearbox.
5. Press the Program button once to assure that you are in Run Mode. You
must be in Run Mode for programmed events to occur. If you are in Run
Mode the colon should blink once per second.
6. Push the Prime button and try to prime the pump. If the pump does
prime, check that events are properly programmed.
For 115 VAC & 230 VAC Versions
1. Verify the power is connected.
2. Check for 6 to 11 volts in the wire harness from the power PCB
to the main PCB. If the voltage is absent, replace the power
PCB.
3. Check for 6 volts DC or greater at the motor connection wires
with the motor disconnected and the pump Prime button
activated. If this voltage is present, replace the motor gearbox.
If the voltage is absent, replace the main PCB.
For D-Cell Battery Power Version
1. Make sure that the batteries are properly aligned and that the
polarity of the wires running from battery pack to the main PCB
is correct.
2. Check for 4.5 volts DC or greater coming from the battery
holder. If voltage is absent, replace the batteries. If voltage is
present, proceed with step 3.
3. Check for 4.5 volts DC or greater at the motor connection wires
with the motor disconnected and the pump Prime button
activated. If this voltage is present, replace the motor gearbox. If
the voltage is absent, replace the main PCB.
Clock Resets to 12:00 AM & Events are Erased When Unplugged or
Power Lost:
Replace backup battery.
Pump Will Not Operate When Programmed Interval Occurs:
Check Event programming. If setup is correct, and the prime switch activates
the pump, replace the main PCB.