Owner`s manual
Figure 1a. HS115
Figure 1b. HS115 D-Cell
Battery Unit
Swimming pool
Calculation Example
30'
40'
1,200 / 400 = 3 oz. / day
Hot Tub
Calculation Example
10' D
'
10' Diameter:
3.14 x (5x5) = 78 oz.
78 / 50 = 1.5 oz. / day
General Information
The HS115 is an Automatic Metering System for the application of Heatsavr™,
the original liquid solar pool cover. It is a reliable, accurate, inexpensive way to
ensure that your pool receives all the energy savings possible from using
Heatsavr™.
The HS115 is a time-activated, water-resistant peristaltic pump. Up to 24
events may be programmed with variable run times for each event from 1
second to 20 minutes. The HS115 operates a 7-day clock in which events can
be programmed to occur every day or only on particular days throughout the
week. A back up battery keeps the clock running in the event of an
interruption in the electrical power. The Automatic Metering System is sold
complete with two peristaltic pump tubes and additional accessories included
(See Accessories). The HS115 is available for use with 115VAC, 230VAC or with
a D-cell battery pack.
The manufacturer recommended dosage rate for Heatsavr™ is 1 oz/400
square feet of pool surface area per day. And 1 oz/50 square feet of Hot Tub
and Spa surface area per day. The higher temperature in Hot Tubs require a
higher dosage rate. The dosage is daily as the product is biodegradable. Each
system can be programmable to exactly fit the surface area of your pool.
Calculate the surface area of your pool (Width x Length) and divide by 400
square feet (50 square feet in Hot Tubs). This will calculate the daily amount
of Heatsavr™ (in ounces) necessary for your specific swimming pool. For
example, a 1,200 sq ft swimming pool will require 3 ounces per day.
The best application time is in the evening, once the swimming pool is closed
to the public or when the swimming pool is experiencing less use.
Installation is very simple and the metering system is durable and easy to
maintain.
Specifications
Operating Conditions
Ambient Operating Temperature: 35 to 104°F (5 to 40°C)
Altitude: <2000 meters (6500 feet)
Humidity: 0 to 100% relative humidity (non-condensing) throughout
temperature range.
Electrical Power Options
115VAC 50/60 Hz +/- 10%
230VAC 50/60 Hz +/- 10%
4 D-cell battery powered
Rating
Pollution Degree: 2
Installation Category II
Intended for indoor use.
Outdoor use requires an All Weather Cover to be installed
Timing Capability
Up to 24 different times. Daily, weekly, or mixed schedule; variable run time 1
second to 19 minutes and 59 seconds.
3