Owner`s manual

E : 0 1
DR1000MF02
Figure 6a.
8 : 3 0
1 2 3 4 5 6 7
DR2000MS07
Figure 6b.
1 : 0 0
M I N : S E C
DR2000MS05.1
Figure 6c. indicates that the
event will have duration of 1
minute
a. Select each day individually, as days 1 through 7, 1 representing
Monday.
b. Select all the days of the week, 1 through 7 appear
together (recommended). Fig. 6b. indicates that the event
will occur everyday at 8:30 AM
c. Select week days only, 1 through 5 appear together
d. Select weekend days only, 6 and 7 appear together
Programming How Long an Event Will Last:
Once you have programmed when the event will occur, press the Event button
again. Min:Sec will appear in the bottom of the screen to indicate the duration
of the Event. The maximum run time is 19 minutes and 59 seconds. Set the
duration of the event using the Minutes button and the Seconds button. We
recommend you allow an interval of 20 minutes between events.
Once you have finished programming the first event, press the Event button
again to move to next event. You can program up to 24 events this way.
However, a normal Heatsavr
TM
injection schedule should only use 1 event,
which will occur each day of the week.
In situations where two events have been programmed for the same time and
day, the highest numbered event will be the one the HS115 accepts. For
example, if Event 1 is set for 30 seconds at 2:00 PM on Day 1 and Event 4 is set
for 10 seconds at 2:00 PM on day 1, Event 4 will take precedence and the
pump will activate for 10 seconds at 2:00 PM on Day 1.
Clearing Unwanted Events
As a rule, it is a good idea to clear events that you do not plan to use. This
eliminates the occurrence of any unwanted events. To clear unwanted events:
1. Go to the event screen of the first event you want to clear.
2. Press and hold the Hours and Minutes buttons at the same time.
3. While still pressing the Hours and Minutes buttons, press and hold the
Event button. The unit will scroll through all higher-numbered events
and clear them (by setting the duration to “000”). The unit will stop
clearing after event 24.
Example of clearing unwanted events
Let’s say you’ve programmed events 1 through 5 and are not planning to use
events 6 through 24. It is advisable to be sure that there are no events
programmed for 6 through 24. To do this:
1. Go to the Event 6 screen.
2. Press the Hours, Minutes and Event buttons and hold them down
simultaneously. The unit will scroll from Event 6 through 24, setting all
values to “000”. This process will stop when it returns to Event 1. You
now have Events 1 through 5 as you programmed them and Events 6
through 24 cleared.
Returning to Run Mode
When you have finished programming, you can return to Run Mode by
pressing the Program button once. The colon will flash normally again (once
per second). If you leave the HS115 in Program Mode and unattended for 2 1/2
minutes, it will switch back into Run Mode automatically.
You can be sure you are in Run Mode by pressing the Prime button and
priming the pump. The Prime button will not prime the pump if you are not in
Run Mode.