Installation Guide

802411 - HT Compact Commercial BC, BCHA -AV, AIO, Installation Instructions - Aug 2015 - V2.01 Page 27 of 40
Booster Specifications:
Rating Unit
Nominal Power Rating 2.2 kW
Nominal Current 10 A
Electric Supply 50Hz AC 230 V
Elect • ex and plug (black) - 1 meter length (with 90º Aus-
tralian plug)
10 A
Fixed Flow Rate 1.2 L/min
Minimum water pressure 200 kPa
Section 3
Booster Heater
Mount base
Horizontally
3.1 Product Description
The boost unit is a compact electronically
controlled auxillary water heater. It is intended to
provide pre heating of water before it enters the
Zip HydroTap G4 boiling tank. The Booster is
supplied as standard equipment with all 140 cup
models. However, it may be later installed, as an
accessory for the 100 cup models, to increase
their delivery to 140 cups.
280mm
Note1: water connection
:Blue marking - water in
:Red marking - water out.
The braided hoses cannot be
lengthened.
Note2: The electrical cable
length is 1.0 metre.
Note3: Position the Booster
within reach of the fixed hose
lengths, keeping the Booster
as close as possible to the
undersink unit inlet/ outlet
fittings.
Note4: Ensure the Booster
heater is mounted in an
upright position (as shown)
with a horizontal base