Declaration of Conformity We, Manufacturer ZIPPY TECHNOLOGY CORP. 10F,No.50,MIN CHYUAN RD. SHIN-TIEN, TAIPEI HSIEN TAIWAN, R.O.C.
MODEL : MRG-5800V4V REPORT NO. : 10090203 APPLICATION FOR CERTIFICATION ON Behalf Of ZIPPY TECHNOLOGY CORP. SWITCHING POWER SUPPLY Model# : MRG-5800V4V FCCID:N/A PREPARED FOR: ZIPPY TECHNOLOGY CORP. 10F,No.50,MIN CHYUAN RD. SHIN-TIEN, TAIPEI HSIEN TAIWAN, R.O.C REPORT BY: ZIPPY TECHNOLOGY CORP. 10F,No.50,MIN CHYUAN RD. SHIN-TIEN, TAIPEI HSIEN TAIWAN, R.O.
MODEL : MRG-5800V4V REPORT NO. : 10090203 TABLE OF CONTENTS Description Page 1. Test Report Certification…………………………………………………………….. 5 2. General Information………………………………………………………………….. 6 2.1 Production Description………………………………………………………………….…….. 6 2.2 Tested System Details……………………………………………………………….………... 7 2.2.1 Resistor Load…………………………………………………………………………….. 7 2.3 Test Methodology…………………………………………………………………………….. 7 2.4 Test Facility……………………………………………………………………………………. 7 3.
MODEL : MRG-5800V4V REPORT NO. : 10090203 TABLE OF CONTENTS Description Page 5. Radiated Susceptibility Measurement……………………………………………. 20 5.1 Test Equipment…………………………………………………………………………….…... 20 5.2 Block Diagram of Test Setup………………………………………………………………… 20 5.3 Severity Levels………………………………………………………………………….…….. 21 5.4 EUT Operating Condition…………………………………………………………………….. 21 5.5 Test procedure…………………………………………………………………….…….…….. 21 5.6 Test Method……………………………………………………………………………….…… 21 5.
MODEL : MRG-5800V4V REPORT NO. : 10090203 1. Test Report Certification Applicant : ZIPPY TECHNOLOGY CORP. Manufacturer : ZIPPY TECHNOLOGY CORP. EUT Description : Switching Power Supply (A) FCC ID : N/A (B) Model No. : MRG-5800V4V (C) Serial No. : N/A (D) Power Supply : 115Vac/60Hz,230Vac/50Hz MEASUREMENT PROCEDURE USED : EN 55024 RULES EN 55022 RULES THE DEVICE DESCRIBED ABOVE WAS TESTED BY ZIPPY SHIN JIUH CORP.
MODEL : MRG-5800V4V REPORT NO. : 10090203 2. General Information 2.1 Production Description Description : Switching Power Supply Model Number : MRG-5800V4V Applicant : ZIPPY TECHNOLOGY CORP. Address : FCC ID : N/A Data Cable : N/A PowerCord : Non-Shielded, detachable, 1.5m 10F,No.50,MIN CHYUAN RD. SHIN-TIEN, TAIPEI HSIEN TAIWAN, R.O.
MODEL : MRG-5800V4V REPORT NO. : 10090203 2.2 Tested System Details The FCC IDs for all equipment, plus descriptions of all cables used in the tested system (including inserted cards, which have grants) are: 2.2.1 Resistor Load Model Number : ELECTRONIC LOAD Serial Number : N/A FCC ID : N/A Manufacturer : ZIPPY Power : 800W 2.
MODEL : MRG-5800V4V REPORT NO. : 10090203 3. Electronic-Magnetic Interference Test 3.1 Conducted Power Line Test 3.1.1 TEST Equipment's The following test equipment's are used during the conducted power line tests: Item 1 Instrument Manufacture Type No: Last Calibration TEST RECEIVER ROHDE & SCHWARZ ESHS10 2 LISN 3 COMPUTER Acer Power8000 N/A 4 PRINTER EPSON 5700L N/A 5 ROHDE & SCHWARZ ENV4200 Mar.,2010 SHIELDED ROOM 4.0M*3.0M*3M Jan.,2010 N/A 3.1.
MODEL : MRG-5800V4V REPORT NO. : 10090203 3.1.3 Conducted Powerline Emission Limit Maximum RF Line Voltage dB(uV) Frequency Class B MHz QUASI-PEAK AVERAGE 0.15 - 0.50 66-56 66-56 0.50 - 5.0 56 56 5.0 - 30 60 60 Remarks : In the Above Table, the tighter limit applies at the band edges. 3.1.4 EUT Configuration on Measurement The equipment's which is listed 3.
MODEL : MRG-5800V4V REPORT NO. : 10090203 Conducted Emission Data DATE OF TEST : SEP,02,2010 TEMPERATURE :26℃ :65% EUT : SWITCH POWER SUPPLY HUMIDITY TEST MODE : MRG-5800V4V DISPLAY PATTERN :N/A Frequency Reading Level dBuV Limites MHz Line 1 Line 2 DBuV 0.206 54.01 53.34 63.37 0.344 46.91 45.85 59.11 29.95 41.85 43.72 60.00 Remark:All readings are Quasi-Peak values.
ZIPPY EMC LAB conduction test EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Scan Settings Start 150kHz 500kHz 5MHz Transducer MRG-5800V4V SPS ZIPPY TECH CO..LTD FULL LOAD EDMENT EN 55022-- Class B Load Condition( 50 21 0.8 19 3.5 ) L220V (3 Ranges) Frequencies Stop 500kHz 5MHz 30MHz No.
ZIPPY EMC LAB conduction test EUT: Manuf: Op Cond: Operator: Test Spec: Comment: MRG-5800V4V SPS ZIPPY TECH CO..LTD FULL LOAD EDMENT EN 55022-- Class B Load Condition( 50 21 0.8 19 3.5 ) L220V Scan Settings (3 Ranges) Frequencies Stop 500kHz 5MHz 30MHz Start 150kHz 500kHz 5MHz Transducer No.
ZIPPY EMC LAB conduction test EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Scan Settings Start 150kHz 500kHz 5MHz Transducer MRG-5800V4V SPS ZIPPY TECH CO..LTD FULL LOAD EDMENT EN 55022-- Class B Load Condition( 50 21 0.8 19 3.5 ) N220V (3 Ranges) Frequencies Stop 500kHz 5MHz 30MHz No.
ZIPPY EMC LAB conduction test EUT: Manuf: Op Cond: Operator: Test Spec: Comment: MRG-5800V4V SPS ZIPPY TECH CO..LTD FULL LOAD EDMENT EN 55022-- Class B Load Condition( 50 21 0.8 19 3.5 ) N220V Scan Settings (3 Ranges) Frequencies Stop 500kHz 5MHz 30MHz Start 150kHz 500kHz 5MHz Transducer No.
MODEL : MRG-5800V4V REPORT NO. : 10090203 3.2 Radiation Emission Test 3.2.1 Test Equipment The following test equipment's are used during the radiated emission test : Instrument Manufacture Type No: Spectrum Analyzer H.P 8594A May.,2010 Test Receiver IFR System A-7550 Jun.,2010 Preamplifier H.P 8447D May.,2010 Biconical Ant. Emco 3110 Jun.,2010 Log-Periodic Ant. Emco 3146 Jun.,2010 Dipole Antenna Emco 3121C May.,2010 3.2.2 Test Setup 3.2.2.
MODEL : MRG-5800V4V REPORT NO. : 10090203 3.2.2.2 Open Field Test Site - description The open field test site (OFTS) is designed to provide an environment in which repeatable tests of radiated emissions can be carried out. It consists of a flat elliptical area as shown in the diagram below. The equipment under test and the antenna are placed at the foci of the ellipse. The antenna height should be remotely adjustable from 1m to 4m.
MODEL : MRG-5800V4V REPORT NO. : 10090203 3.2.4 EUT Configuration The equipment's which is listed 4.2.1 are installed on Radiated Emission Test to meet the Commission requirement and operating in a manner which tends to maximize its emission characteristics in a normal application. 3.2.5 Operation Condition of EUT Same as Conducted Power Line Test which is listed in 3.1.5 . 3.2.6 Radiated Emission Data The measurement range of radiated emission which is from 30 MHz to 1000 MHz was investigated.
MODEL : MRG-5800V4V REPORT NO.
MODEL : MRG-5800V4V REPORT NO.
MODEL : MRG-5800V4V REPORT NO.
MODEL : MRG-5800V4V REPORT NO. : 10090203 4. ESD Measurement 4.1 Test Equipment The following test equipment's are used during the ESD test : Instrument Manufacture Type No: Last Calibration ESD Simulator system Keytek MZ-15/EC May.,2010 Electronic Load D-RAM Load-2000 N/A 4.2 Test Setup 4.2.1 Block Diagram of Connections between EUT and simulators ESD Simulator system EUT 4.2.
MODEL : MRG-5800V4V REPORT NO. : 10090203 4.3 Severity Levels LEVEL TEST VOLTAGE CONTACT DISCHARGE TEST VOLTAGE AIR DISCHARGE 1 2KV 2KV 2 4KV 4KV 3 6KV 6KV 4 8KV 8KV X SPECIAL SPECIAL 4.4 EUT Operating Condition 1. Setup the EUT and Test Equipment as shown on 4.2 2. power on. 4.5 Test Procedure Air Discharge: This test was done above a non-conductive surfaces. The round discharge electrode about 30cm away will approach as fast as possible to touch test points of the EUT.
MODEL : MRG-5800V4V REPORT NO. : 10090203 4.
MODEL : MRG-5800V4V REPORT NO. : 10090203 5. Radiated Susceptibility Measurement 5.1 Test Equipment The following test equipment's are used during the RS test : Instrument Manufacture Type No: Last Calibration Signal generator H.P 8657A Dec.,2009 Power amplifier A&R 100A100 Dec.,2009 Field strength meter A&R FM2000 Oct.,2009 Field strength sensor A&R EP2000 Oct.,2009 Power antenna A&R AT1080 Oct.,2009 5.
MODEL : MRG-5800V4V REPORT NO. : 10090203 5.3 Severity Levels LEVEL FIELD STRENGTH V/M 1 1 2 3 3 10 X SPECIAL 5.4 EUT Operating Condition Same as section 4.4. 5.5 Test Procedure The EUT and load are placed on a table which is 0.8 meter above ground. The field sensor is also placed on the same table to monitor field strength from transmitting antenna. EUT is set 1 meter away from the transmitting antenna which is mounted on an antenna each time. The antenna is fixed 1 meter above ground.
MODEL : MRG-5800V4V REPORT NO. : 10090203 5.
MODEL : MRG-5800V4V REPORT NO. : 10090203 6. Electrical Fast Transient / Burst Measurement 6.1 Test Equipment The following test equipment's are used during the EFT tests : Instrument Manufacturer Type No. Last Calibration Fast Transient / Burst enerator Keytek EMCpro May.,2010 6.2 Block Diagram of Test Setup 6.3 Severity Levels Open Circuit Output Test Voltage +/- 10% Level On power supply lines 1 0.
MODEL : MRG-5800V4V REPORT NO. : 10090203 6.4 EUT Operation Condition Same as section 4.4. 6.5 Test Procedure The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured 1m*1m min. And 0.65 mm thick min. And projected beyond the EUT by at least 0.1m on all sides.
MODEL : MRG-5800V4V REPORT NO. : 10090203 6.
MODEL : MRG-5800V4V REPORT NO. : 10090203 7. Harmonic Current Test DATE OF TEST : SEP,02,2010 TEMPERATURE :26℃ :65% EUT : SWITCH POWER SUPPLY HUMIDITY TEST MODE : MRG-5800V4V DISPLAY PATTERN :N/A Item 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Reading Leve A A Limites 4.153 0.447 0.146 0.054 0.030 0.014 0.013 0.011 0.009 0.008 0.006 0.005 0.003 0.002 0.001 0.001 0.003 0.003 0.004 0.004 Item 2.300 1.140 0.770 0.400 0.330 0.210 0.150 0.132 0.118 0.107 0.098 0.090 0.083 0.078 0.073 0.
MODEL : MRG-5800V4V REPORT NO.
MODEL : MRG-5800V4V REPORT NO.
MODEL : MRG-5800V4V REPORT NO. : 10090203 8. Voltage Fluctuation And Flicker Test DATE OF TEST : SEP,02,2010 TEMPERATURE :26℃ :65% EUT : SWITCH POWER SUPPLY HUMIDITY TEST MODE : MRG-5800V4V DISPLAY PATTERN :N/A Item Reading Limit Result Pst 0.000 1.00 Pass P1t 0.000 0.65 Pass Dc (%) 0.000 3.00 Pass Dmax (%) 0.000 4.00 Pass Dt (%) 0.000 0.
MODEL : MRG-5800V4V REPORT NO. : 10090203 9. Surge Immunity Test DATE OF TEST : SEP,02,2010 TEMPERATURE :26℃ :65% EUT : SWITCH POWER SUPPLY HUMIDITY TEST MODE : MRG-5800V4V DISPLAY PATTERN :N/A Wavefor Voltage Output:LC Phs Ref Phs Ang Tests Delay Result 12 Ohm -2000V MAINS:L1/PE L1 0 deg. 5 60 sec Pass 12 Ohm -2000V MAINS:L1/PE L1 90 deg. 5 60 sec Pass 12 Ohm -2000V MAINS:L1/PE L1 270 deg. 5 60 sec Pass 12 Ohm 2000V MAINS:L1/PE L1 0 deg.
MODEL : MRG-5800V4V REPORT NO. : 10090203 10. Conducted Immunity Test DATE OF TEST : SEP,02,2010 TEMPERATURE :26℃ :65% EUT : SWITCH POWER SUPPLY HUMIDITY TEST MODE : MRG-5800V4V DISPLAY PATTERN :N/A Frequency Range (MHz) Polarity (HorV) Field Strength (V/M) Results 0.
MODEL : MRG-5800V4V REPORT NO. : 10090203 11. Voltage Dip, Interruptions Immiunity Test DATE OF TEST : SEP,02,2010 TEMPERATURE :26℃ :65% EUT : SWITCH POWER SUPPLY HUMIDITY TEST MODE : MRG-5800V4V DISPLAY PATTERN :N/A Test Voltage AC 115V AC 230V Phase Reduction Duration % Angle (Periods) 0 deg. 0.5 90 deg. 0.5 >95% 180 deg. 0.5 270 deg. 0.5 0 deg. 25 90 deg. 25 30% 180 deg. 25 270 deg. 25 0 deg. 250 90 deg. 250 >95% 180 deg. 250 270 deg. 250 0 deg. 0.5 90 deg. 0.5 >95% 180 deg. 0.5 270 deg. 0.
MODEL : MRG-5800V4V REPORT NO. : 10090203 12. Photographs 1.Front view of Power Supply 2.
MODEL : MRG-5800V4V REPORT NO. : 10090203 3.Front view of Power Supply 4.
MODEL : MRG-5800V4V REPORT NO. : 10090203 5.Component side of Mainboard 6.
MODEL : MRG-5800V4V REPORT NO. : 10090203 7.Component side of Mainboard 8.
MODEL : MRG-5800V4V REPORT NO. : 10090203 9. Inside view of Power Supply 10.
MODEL : MRG-5800V4V REPORT NO. : 10090203 11.Inside view of Power Supply 12.
MODEL : MRG-5800V4V REPORT NO. : 10090203 13. EMI Reduction Method During Compliance Testing 1.No modification was made during test.