Owner's Manual
Preparing the LaserVision® Plumb Pyramid® for Use
For safety, the laser exit hole has been covered with a protective sticker. Remove the sticker before
using the LaserVision® Plumb Pyramid®.
Replacing the Batteries
The typical battery life for the LaserVision® Plumb Pyramid® is approximately 12 hours of
continuous use.
If the laser line becomes dim, you may want to replace the batteries. To do this:
Ensure unit is turned off.
Turn over the plumb pyramid and remove the two screws from the bottom of the unit.
Remove the base and replace the batteries.
Put the base back on and secure with the screws.
Using LaserVision® Plumb Pyramid®
Place the LaserVision® Plumb Pyramid® on a smooth, stable, relatively level surface (within
5° side-to-side and front-to-back).
To turn unit on, press the power switch. The red LED just above the power switch will
illuminate and a vertical laser line will be produced when the LaserVision® Plumb Pyramid®
is on.
Point the unit so that the vertical laser line is projected onto the desired surface.
The LaserVision® Plumb Pyramid® contains a precision self-leveling mechanism. It will
compensate for a surface tilted up to 5°. If you suspect the LaserVision® Plumb Pyramid® is
out of its self-leveling range and is no longer producing a plumb line, tilt the unit slightly in
each direction and observe the line on the wall to see if the line corrects to plumb. If while
tilting in one of the direction it does not correct, then the unit is out of range in that direction
and a more level surface needs to be found.
The LaserVision® Plumb Pyramid® is equally sensitive to tilt front-to-back. To ensure that
your surface is within the self-leveling range in this direction, you should turn the unit 90° and
repeat the previous step. This will ensure that the unit is within range in both directions. Then
turn it back to the desired direction.
To turn unit off, press and release the power switch. When not in use, always return the unit
to its carrying case to prevent damage.
NOTE:
The LaserVision® Plumb Pyramid® will not automatically turn off. Therefore, to maximize battery