Quick Start Guide

2
1) In "Trigger Read" work mode, the reader will not read cards before a low level
signal to "Trigger Point" is delivered. "Trigger Point" is mainly used for
working with the ground sensor of vehicle parking system.
2) In "Always Read" work mode, once the card is in the effective range, the
reader will output the card number via Wiegand continually.
3. Technical Parameter
Working Voltage
DC9V ~ 12V
Working Current
1.2A +/-10%
Working Temperature
-20 ~ +60
Working Humidity
<95%(+25°C)
Interface Protocol
EPC global UHF Class 1Gen2/ ISO 18000-
6C,ISO
18000-6B
Working Frequency
865MHz~868MHz;920MHz~925MHz
Output Power
10dBm ~ 33dBm
Communication Interface
Wiegand 26/34; USB
Reading Distance
Stable 18 meters
Atenna Gain
9dBI
Dimension
310mm*310mm*90mm(±5mm)
Length of cable
1400±50mm
4. Safety Precautions
1) The reader working voltage ranges from DC9V to DC16V, it is recommended
to use DC12V /3A power supply.
2) Please wire according to the cable definition.
5. Modifying Setting via Demo