10 Access Control
Access Control option is used to set the Time Schedule, Holidays, Access Groups, Combined Verification etc., the related
parameters for the device to control the lock and other devices.
Tap [Access Control] on the main menu interface.
10.1 Access Control Options Settings
To set the parameters of the equipment control lock and related equipment.
Tap Access Control Options on the Access Control interface.
Menu Item Description
Door Lock Delay (s)
The period of time of unlocking (from door opening to closing automatically) after the
electronic lock receives an open signal sent from the device (value ranges from 0 to 10
seconds).s
Door Sensor Delay (s)
When the door is opened, the door sensor will be checked after a time period; if the state of
the door sensor is inconsistent with that of the door sensor mode, alarm will be triggered.
The time period is the Door Sensor Delay (value ranges from 1 to 255 seconds).
Door Sensor Type
It includes Normally Open, Normally Closed and No. No means door sensor is not in use;
Normally Open means the door is opened when electricity is on; Normally Closed means
the door is closed when electricity is on.
Door Alarm Delay (s)
When the state of the door sensor is inconsistent with that of the door sensor type, alarm
will be triggered after a time period; this time period is the Door Alarm Delay (the value
ranges from 0 to 999 seconds).
To gain access, the registered user must meet the following
conditions:
1. User’s access time falls within either user’s personal time zone or
group time zone.
2. User’s group must be in the access combo (when there are other
groups in the same access combo, verification of members of
those groups are also required to unlock the door).
In default settings, new users are allocated into the first group
with the default group time zone and access combo as “1(, and set