Access Control Options 10.1
Tap Access Control Options on the Access Control interface to set the parameters of the control lock of
the terminal and related equipment.
Function Description
Function Name
Description
Gate Control Mode
Toggle between ON or OFF switch to get into gate control mode or not.
When set to ON, on this interface will remove Door lock relay, Door sensor
relay and Door sensor type options.
Door Lock Delay (s)
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1~10 seconds; 0 second represents disabling the function.
Door Sensor Delay (s)
If the door is not locked and is being left open for a certain duration (Door Sensor
Delay), an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door Sensor Type
There are three Sensor types: None, Normal Open and Normal Closed.
None: It means door sensor is not in use.
Normal Open: It means the door is always left opened when electric power is on.
Normal Closed: It means the door is always left closed when electric power is on.