Anti-passback Setup 10.5
It is possible that users may be followed by some persons to enter the door without verification, resulting
in a security breach. So, to avoid such a situation, the Anti-Passback option was developed. Once it is
enabled, the check-in record must match with the check-out record so as to open the door.
This function requires two devices to work together: one is installed inside the door (master device), and
the other one is installed outside the door (slave device). The two devices communicate via the Wiegand
signal. The Wiegand format and Output type (User ID / Card Number) adopted by the master device and
slave device must be consistent.
Tap Anti-passback Setup on the Access Control interface.
Function Description
Function Name
Description
Anti-passback
direction
No Anti-passback: Anti-
passback function is disabled, which means
successful verification through either the master device or slave device can
unlock the door. The attendance state is not saved in this option.
Out Anti-passback: After a user checks out, only if the last record is a check-in
record, the user can check-out again; otherwise, the alarm will be triggered.
However, the user can check-in freely.
In Anti-passback: After a user checks in, only if the last record is a check-out
record, the user can check-
in again; otherwise, the alarm will be triggered.
However, the user can check-out freely.
In/Out Anti-passback:
After a user checks in/out, only if the last record is a
check-out record, the user can check-in again; or if it is a check-in record, the
user can check-out again; otherwise, the alarm will be triggered.