User's Manual

Table Of Contents
4-inch Visible Light Terminal
User Manual
Page | 44 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
Function Description
Function Name
Descriptions
SRB
When SRB is enabled, the lock is controlled by the SRB to prevent the lock
from being opened due to device removal.
Wiegand Format
Values range from 26 bits, 34 bits, 36 bits, 37 bits, and 50 bits.
Wiegand output bits
After selecting the required Wiegand format, select the corresponding output bit
digits of the Wiegand format.
Failed ID
If the verification is failed, the system will send the failed ID to the device and
replace the card number or personnel ID with the new one.
Site Code
It is similar to the device ID. The difference is that a site code can be set manually,
and is repeatable in a different device. The valid value ranges from 0 to 256 by
default.
Pulse Width(us)
The time width represents the changes of the quantity of electric charge with
regular high-frequency capacitance within a specified time.
Pulse Interval(us)
The time interval between pulses.
ID Type
Select the ID types as either User ID or card number.
Network Diagnosis 6.7
To set the network diagnosis parameters.
Tap Network Diagnosis on the Comm. Settings interface to set the IP address diagnostic and Start the
diagnostic parameters.