User's Manual

Table Of Contents
4-inch Visible Light Terminal
User Manual
Page | 63 Copyright©2020 ZKTECO CO., LTD. All rights reserved.
Verification Mode
The supported verification mode includes Password/F
ace, User ID only,
Password, Face only, and Face + Password.
Door available time
period
To set time period for door, so that the door is available only during that
period.
Normal open time
Period
Scheduled time period for “Normal Open” mode, so that the door is always
left open during this period.
Master Device
When setting up the master, the status of the master can be set to exit on
enter.
Out: The record verified on the host is the exit record.
In: The record verified on the host is the entry record.
Slave Device
When setting up the slave, the status of the slave can be set to exit on enter.
Out: The record verified on the host is the exit record.
In: The record verified on the host is the entry record.
Auxiliary input
configuration
Sets
the door unlock time period and auxiliary output type of the auxiliary
terminal device.
Auxiliary output types include None, Trigger door open,
Trigger Alarm, Trigger door open and Alarm.
Verify mode by
RS485
The verification mode is used when the device is used either as a host or
slave.
The supported verification mode includes Card Only, Card + Password.
Speaker Alarm
Transmits a sound alarm or disassembly alarm from the local. When the door
is closed or the verification is successful, the system will cancel the alarm from
the local.
Reset Access Setting
The access control reset parameters include door lock delay, doo
r sensor
delay, door sensor type, verification mode, door available time period, normal
open time period, master device, and alarm. However, erased access control
data in Data Mgt. is excluded.
Time Rule Setting 10.2
Tap Time Rule Setting on the Access Control interface to configure the time settings.
The entire system can define up to 50 Time Periods.
Each Time Period represents 10 Time Zones, i.e. 1 week and 3 holidays, and each time zone is a
standard 24 hour period per day and the user can only verify within the valid time period.
One can set a maximum of 3 time periods for every time zone. The relationship among these time
periods is "OR". Thus when the verification time falls in any one of these time periods, the
verification is valid.