b) The user can set the parameter information of the card reader by himself, and then
click "write configuration" to configure the parameter information of the QR code
reader
Params
Description
RS485 address
0: Broadcast address, that is, no matter the machine's 485 address is
set to 0~255, it can be connected by communication.
If the 485 address of the machine is set to 1~255, fill in the
corresponding, and it can also be connected by communication
Unlock time
When the card reader is directly connected to the door lock and the
card/QR code with normal door opening permission is swiped, the door
opening time
serial number
Device serial number of the card reader
RS485 Function
Turn on/off the RS485 communication mode of the card reader.
The configuration tool can still be connected through 485 when closed
RS485 Active
upload
When it is turned on, the card reader data is automatically uploaded to
the server under the 485 interface.
When closed, the card reader data will not be uploaded to the server
Wiegand
Function
Turn on or off Wiegand mode.
Note: The DEMO switch has no effect. Wiegand output is also available
when the Wiegand mode is turned off
Work mode
Reading head mode: When connecting a card reader, select the reading head
mode, and set the parameters of the reading head through the DEMO
software.
Note: Only reader mode is supported!
HID keyboard
When it is turned on, the USB communication can transfer the card number
(the card does not support)/QR code data to the computer (such as a text
file).
When closed, the card/QR code will have normal feedback, but the USB will