Quick Start Guide

12
15 Detection Management Settings
L
Click on enter the management interface > [System] > [Detection Management]to detection . You
can set the value of High temperature alarm threshold. The device will send an alarm prompt when
the temperature of the user detected exceeds this value. When the Temperature over the range;
access denied is enabled, the user will be forbidden to access, as shown in the following figure.
Temperature over the range; access denied
Deny access without mask
Enable mask detection
Temp. Unit
Temperature deviation correction
Low temperature alarm threshold
High temperature alarm threshold
Enable temperature screening with infrared
Detection Management
08:50
Normal temperature
Measure Temp.
O
Temp.: 36.65 C
Mask Detected
Successfully verified
Name:Mike
User ID:4835
Verify:Face
08:50
Measure Temp.
Successfully verified
Name:Mike
User ID:4835
Verify:Face
Temperature over the range
O
Temp.: 37.65 C
Without mask
L