User's Manual
6 FD1043V User Manual
In order to avoid the influence of the self-induced electromotive force produced by the electric lock on the access
control system, a diode in parallel need to be connected on the electric lock, when the access controller is connected.
Select FR107 diode with a faster response speed. FR107 diode has positive (shown as “+” in the figure) and negative
(shown as “-” in the figure) poles. At the time of wiring, connect the “+” of diode to the “-” of electric lock and the “-”
of diode to the “+” of electric lock. Keep the diode as close as possible to the electric lock.
1.4.3 Wiegand Output Connection
When the FaceDepot device needs to connected to the controller through Wiegand output, connect GND, WD1 and
WD0 of the controller's Wiegand input to the GND, WD1 and WD0 of J8 interface.
1.4.4 Recommended Identification Distance
The recommended identification distance is about 1m to 5 m from the face of the device. Recommended distance
is about 3 m, shown in the following figure.