Reader Start Get FP template, 1 beep, light off, switch to 485 Y Getting control order timeout? N Only FP verification? Y N Y FP or card verification? N N Send FP template to access control panel Get card number already?? Y Y N Send card number and FP template to access control panel Y FP and card verification? Only card verification? Verification result timeout? N N Y Pass the verification? Y Prompt: 3 beeps, green LED on Prompt: 1 beep, green LED on Prompt: 2 beeps, red LED on Reader
7
Reader Start Get card, 1 beep, light off, switch to 485 Y Getting control order timeout? N Only card verification? Y N Y FP or card verification? Send card number to access control N Y Y Verification result timeout? N N N Pass the verification? N Prompt: 1 beep, green LED on Send no data to access control panel, switch to main mission, waiting for FP and follow the verification process of press FP first Prompt: 2 beeps, red LED on Reader Stop 8 FP and card verification? Y Y Prompt:
9
10
11
FCC Caution: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NO.