3.5ConnectionwithDoorSensors,ExitSwitches,and
AuxiliaryInputDevices
Doorsensor
A door sensorisusedtosensetheopen/closedstatusofadoor.Withadoor sensor
switch,anaccesscontrolpanelcandetectillegalopeningofadoor,andwilltrigger
an output of alarm. Moreover, if a dooris not closed within a specified period of
time after it is opened, the door control panel will also prompt an alarm. It is
recommendedtoselecttwocorewireswitha gauge over0.22mm
2
. Adoorsensormaybe
omittedifitisunnecessarytomonitoronlinetheopen/closedstatusofadoor,giveoutan
alarm whenthedoorisnot closedfor alongtime orthereisillegal access,and usethe
interlockfunction.
Exitswitch
Anexitswitchisaswitchinstalledindoorstoopenadoor.Whenitisswitchedon,
thedoorwillbeopened.Anexitbuttonisfixedataheightofabout1.4mabovethe
ground.Ensureitislocatedintherightpositionwithoutslant,anditsconnectionis
correct andsecure.(Cut off theexposedendofany unused wireand wrapit with
insulating tape.) Note to guard against electromagnetic interference (such as light
switches and computers). Itis recommendedtousetwocorewireswith agaugeover
0.3mm
2
astheconnectionwirebetweenanexitswitchandacontrolpanel.
Auxiliaryinput
C3100 provides no auxiliary input interface; C3200 provides two, and C3400
providesfour,whichareconnectedtoinfraredbodydetectors,smokedetectors,gas
detectors,windowmagneticalarms,wirelessexitswitches,etc.Auxiliaryinputsare
set through relevant access control software. For details, please see ZKAccess4.0
UserManual.