4.4DIPSwitchSetting(485AddressSetting,Factory
Setting,andTerminalResistanceSetting)
485addresssetting
Places 16 of the DIP switch are reserved to set device number for RS485
communication. The code is binary, and the lower places are in the front.
Whentheswitchissettothe ONposition,itindicates1(on);whentheswitch
issetdownwards,itindicates0(off).
Forexample,tosetadevicenumber39=1+2+4+32,whichcorrespondstothe
binarycode111001,putplaces1,2,3,and6totheONposition,asillustrated
below.
485addresssettingtable:
SwitchSetting
PlaceAddress
1 2 3 4 5 6
AddressNo. 1 2 4 16 32 64
01 ON OFF OFF OFF OFF OFF
02 OFF ON OFF OFF OFF OFF
03 ON ON OFF OFF OFF OFF
04 OFF OFF ON OFF OFF OFF
05 ON OFF ON OFF OFF OFF
06 OFF ON ON OFF OFF OFF
07 ON ON ON OFF OFF OFF
08 OFF OFF OFF ON OFF OFF
09 ON OFF OFF ON OFF OFF
10 OFF ON OFF ON OFF OFF
11 ON ON OFF ON OFF OFF
12 OFF OFF ON ON OFF OFF