Quick Installation Guide
InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
31
4.4DIPSwitchSetting(485AddressSetting,Factory
Setting,andTerminalResistanceSetting)
485addresssetting
Places 16 of the DIP switch are reserved to set device number for RS485
communication. The code is binary, and the lower places are in the front.
Whentheswitchissettothe ONposition,itindicates1(on);whentheswitch
issetdownwards,itindicates0(off).
Forexample,tosetadevicenumber39=1+2+4+32,whichcorrespondstothe
binarycode111001,putplaces1,2,3,and6totheONposition,asillustrated
below.
485addresssettingtable:
SwitchSetting
PlaceAddress
1 2 3 4 5 6
AddressNo. 1 2 4 16 32 64
01 ON OFF OFF OFF OFF OFF
02 OFF ON OFF OFF OFF OFF
03 ON ON OFF OFF OFF OFF
04 OFF OFF ON OFF OFF OFF
05 ON OFF ON OFF OFF OFF
06 OFF ON ON OFF OFF OFF
07 ON ON ON OFF OFF OFF
08 OFF OFF OFF ON OFF OFF
09 ON OFF OFF ON OFF OFF
10 OFF ON OFF ON OFF OFF
11 ON ON OFF ON OFF OFF
12 OFF OFF ON ON OFF OFF