Quick Installation Guide
InstructionsforInstallationandUseoftheC3100/200/400ControlPanel
3
2. It is recommended notto plug/unplug connection terminals frequently when
the system is energized. Be sure to unplug the connection terminals before
startinganyrelevantweldingjob.
3. Donotdetachorreplace anycontrol panelchipwithoutpermission,because
unprofessionaloperationmaycausedamagetothecontrolpanel.
4. It is recommended not to connect any other auxiliary devices without
permission. All nonroutine operations must be communicated to our
engineersinadvance.
5. A control panel should not share one power socket with any other
largecurrentdevice.
6. Itispreferabletoinstallcardreadersandbuttonsatheightsof1.41.5m above
the ground, but the heights are subject to proper adjustment according to
customers’usualpractice.
7. It is advised to install control panels at places easy of maintenance, like a
weakelectricwell.
8. Itisstrongly recommended thattheexposedpartofany connectionterminal
shouldnotbelongerthan4mm,andspecializedclampingtoolsmaybeused
to avoid shortcircuit or communication failure resulting from accidental
contactwithexcessiveexposedwires.
9. To save access control event records, read data periodically from control
panels.
10. Get prepared countermeasures according to application scenarios for
unexpectedpowerfailure,like selectingpowersupplywithUPS.
11. The connection between a card reader and a control panel should not be
longerthan100m.
12. The connection between a PC and a control panel should be shorter than
1200mforRS485communications.Alengthwithin600m isrecommendedto
makecommunicationsmorestable.