Use and Care Manual

2019
Burner Vent
AR3
Nozzle
Burner Vent
AR3
Burner Vent
Nozzle
STEP 5:
Set the natural gas nozzle
aside and replace with the
propane nozzle. Screw in and
tighten the new nozzle.
STEP 6:
Place the burner vent back into
position over the new nozzle in
the AR3 slot.
STEP 7:
Secure the burner back in
place with the mounting screw
that was removed in step 2.
STEP 8:
Follow steps 2 through 7 with
the bottom burner. Ensure
the nozzles and burners are
secured properly.
INSTALLATION
Gas Conversion Procedure
STEP 4: FLAME ADJUSTMENT
1. Light one burner at a time and set it to the MINIMUM position (small flame).
2. Remove the knob.
3. The range is equipped with a safety valve. Using a small-size flathead
screwdriver, locate the choke screw (see diagram below) and turn to the right or
left until the burner flame is adjusted to desired minimum.
4. Make sure that the flame does not go out when switching quickly from the
MAXIMUM to the MINIMUM position.
The high flame setting cannot be adjusted to be lower. If the height is too high, revisit
the conversion set up. A step may have been missed.
INSTALLATION
2.0 x 50 mm
2.0 x 50 mm
Flame Adjustment
Flame Adjustment
WIRING DIAGRAM
DW7714-18 & DW7713-24
18” & 24“ Panel-Ready Dishwasher
0.0.0.
FLAME ADJUSTMENT
Germania
RA series, RG series
zlinekitchen.com 1-614-777-5004 0.0.0.zlinekitchen.com 1-614-777-5004
2.0 x 50 mm
2.0 x 50 mm
If the customer flame control valve looks like this (left), then they will not be able to adjust the
flame without removing one of the screws. These new ranges are already fielded, so please
do not process returns for this issue. The valves are different from the previous ones and are
not interchangeable.
2.0 x 50 mm
2.0 x 50 mm
Flame Adjustment
SCAN ME
SCAN ME SCAN ME