Use and Care Guide

8
A properly grounded and horizontally-mounted electrical receptacle type NEMA 14-
50R should be installed no higher than 3” above the floor, no less than 2” and not
more than 8” from the left side (facing product); refer to electrical connection section.
Gas
An agency-approved, properly-sized manual shut-off valve should be installed no
higher than 3” aboce the floor and no less than 2” and no more than 8” from the
right side (facing product).
To connect gas between shut-off valve and regulator, use agency-approved,
properly sized flexible or rigid pipe. Check all local code requirements.
Installation Adjacent to Kitchen Cabinets
The range may be installed directly adjacent to existing coutertop height cabinets
(36”) from the floor.
For the best look, the worktop should be level with the cabinet countertop. This can be
accomplished by raising the unit using the adjustment spindles on the legs.
ATTENTION: the range CANNOT be installed directly adjacent to kitchen walls, tall
cabinets, tall appliances, or other vertical surfaces above 36˝ high. The minimum
side clearance in such cases is 6”.
Wall cabinets with minimum side clearance must be installed 30˝ above the
countertop with coun-tertop height between 35.5” and 37.25”. The maximum depth
of wall cabinets above the range shall be 13”.
Installation Requirements