Installation Sheet

5352
Troubleshooting
Troubleshooting
TROUBLESHOOTING
My range hood is not pulling.
Was the unit plugged in and was the fan checked before installation?
What distance is the hood mounted above the cook top?
Indoor (30”-36”), outdoor (36”-40”)
Is the range hood width the correct size for the cook top?
Outdoor units should be at least 1 size larger, if not 2
Does the hood have enough BTU output in relationship to either their gas or
electric stove cook top?
BTU output per burner/100 - for gas
Wattage output per burner/10 - for electric
Are the baffle filters or mesh filters installed correctly? When were they last
cleaned?
Is the ducting clear?
Is the damper opening properly once the hood is turned on?
Is there air coming off the top of the hood?
Is there air coming out of the upper chimney section?
When tissue is placed on the baffle filters under the hood, does it hold the tissue?
How many elbows and how long is the ducting run?
Should be no more than 2-3 elbows and no more than a 40 foot run
to exit, for every elbow subtract 5 feet
Is the air recirculating? When were the carbon filters last changed?
The carbon filters need changed every 3-6 months based on your
cooking habits.
TROUBLESHOOTING
Noisy Motor
Were the fan speeds checked fan speeds prior to installation?
Is the ducting clear?
Check to make sure motor is attached to housing
Is the 6” back draft damper on transition piece functioning properly (760 CFM
hood?) Does it open when the hood is engaged?
If it is stuck, it will sound like motor noise but it’s really the damper
Was a damper installed on the roof or side vent?
Check that the damper is fully functioning by engaging the hood and
checking if it opens and closes properly
If the motor is accessible, the motor knob can be tightened.
Take off the gray cap. You
can tighten the knob here to
eliminate any vibration.