A lpine S eries R ange H oods Installation Guide and Users Manual
SCAN ME REGISTERING YOUR PRODUCT Please register your ZLINE appliance to activate your warranty. Begin the simple registration process by scanning the QR code. ZLINE Kitchen and Bath provides Attainable Luxury, where the kitchen and bath of your dreams is never out of reach. Through our unique designs and unparalleled quality, we’re dedicated to providing you an elevated experience in the heart of your home. With an endless selection of features and finishes, our inspiration is your reality.
WARRANTY WARRANTY PROPER VENTING REGULATIONS WHAT IS NOT COVERED Please verify with your local, city, and state regulations on the proper venting method Consumable parts such as light bulbs, metal and charcoal filters. The natural wear for your hood. Many agencies have CFM rating specifications for your hood, as well.
DISCLAIMER TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS 1 ALPINE WALL HOOD SAFETY 4 ALPINE WALL HOOD INSTALLATION 7 ALPINE WALL HOOD OPERATION 16 ALPINE WALL HOOD MAINTENANCE 17 ALPINE WALL HOOD TROUBLESHOOTING 19 ALPINE UNDER CABINET HOOD SAFETY 20 ALPINE UNDER CABINET HOOD INSTALLATION 23 ALPINE UNDER CABINET HOOD OPERATION 30 ALPINE UNDER CABINET HOOD MAINTENANCE 31 ALPINE UNDER CABINET HOOD TROUBLESHOOTING 33 Carefully inspect all items for damages
SAFETY INSTRUCTIONS This is the safety alert symbol. This symbol alerts you to potential hazards WARNING SAFETY INSTRUCTIONS • Ducted fans MUST ALWAYS be vented to the outdoors. At the point where the that can hurt you and others. All safety messages will follow the safety alert duct work ends, add an external damper to prevent air from entering the home symbol. when the hood is not in use. This also prevents small animals and rain water from entering the duct work.
SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS ALPINE WALL MODELS • All ZLINE range hoods are ETL listed, ensuring all parts were tested for safety and meet industry standards and regulations. NOTE: This ensures all included plastic ducting pieces were tested for safety and are flame retardant. • Always turn the range hood ON when cooking at high heat or when cooking This is the safety alert symbol. This symbol alerts you to potential hazards WARNING that can hurt you and others.
SAFETY INSTRUCTIONS ALPINE WALL MODELS SAFETY INSTRUCTIONS ALPINE WALL MODELS • Ducted fans MUST always be vented to the outdoors. TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A STOVE • Use only metal ductwork and this unit MUST be grounded. TOP GREASE FIRE: • Sufficient air is needed for proper combustion and exhausting of gases through • SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn the duct to prevent back drafting.
BEFORE INSTALLATION ALPINE WALL MODELS BEFORE INSTALLATION ALPINE WALL MODELS TOOLS NEEDED: ELECTRICAL REQUIREMENTS • Contact a qualified electrical installer. • Assure that the electrical installation is adequate and in conformance with Na- Pencil tional Electrical Code, ANSI/NFPA 70 — latest edition, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91 - latest edition and all local codes and ordinances.
BEFORE INSTALLATION ALPINE WALL MODELS BEFORE INSTALLATION ALPINE WALL MODELS ADVANCED PREPARATIONS 1. Be familiar with the controls of the range hood by reading through the Range Hood Operations, page 40. 2. Place the range hood on a flat, stable surface. Connect the range hood to a designated standard outlet, 110~120V/60Hz, AC only, and turn on the range hood. Verify all operations of the range hood by referring to the Range Hood Operations, page 40. 3.
BEFORE INSTALLATION ALPINE WALL MODELS BEFORE INSTALLATION ALPINE WALL MODELS Due to different ceiling height configurations, recommended height may not be applicable. Option 1: Option 1: Horizontal wall venting Horizontal wall venting Option 2: Option 2: CALCULATING VENT SYSTEM LENGTH To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system from the recommended maximum duct run.
BEFORE INSTALLATION ALPINE WALL MODELS 4. 5. 6. INSTALLATION ALPINE WALL MODELS Mark the locations of the support mounting bracket holes, vent cutout (if used), WARNING: HAZARD OF ELECTRIC SHOCK and power supply cable cutout on the ceiling. Use drill and saber saw or Do not perform service on an electrically live system. Disconnect the main electrical keyhole saw to cut openings for power supply cable and vent (see Venting supply before servicing this device.
INSTALLATION ALPINE WALL MODELS 7. OPERATION ALPINE WALL MODELS Calculate the height of the duct tube and extend approximately 6” (15 cm) longer than required, connect the lower end of the duct tube to the range hood and the upper end to the vent system. Make sure the main electrical supply remains disconnected then connect power plug to the electrical cord or wall plug. 8.
MAINTENANCE AND CLEANING ALPINE WALL MODELS HOW TO CHANGE OR REPLACE LIGHT BULB MAINTENANCE AND CLEANING ALPINE WALL MODELS • If hood looks splotchy, use a stainless steel cleaner to clean the surface of 1. Make sure the range hood is unplugged or turn OFF breaker. the hood. Avoid getting cleaning solution on or into the control panel. Follow 2. Slightly press inward on the bulb using both thumbs. directions of the stainless steel cleaner. CAUTION: Do NOT leave on too long 3.
TROUBLESHOOTING ALPINE WALL MODELS SAFETY INSTRUCTIONS ALPINE UNDER CABINET MODELS This is the safety alert symbol. This symbol alerts you to potential hazards ZLINE Customer Service is available at 1-614-777-5004. WARNING Range hood does not operate after installation Range hood vibrates when the blower is on The blowers seems weak The lights work, but the blower is not spinning at all, is stuck, or is rattling. Check if the range hood has been plugged in.
SAFETY INSTRUCTIONS ALPINE UNDER CABINET MODELS SAFETY INSTRUCTIONS ALPINE UNDER CABINET MODELS WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY THE METAL WARNING DUCTWORK. WARNING WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE WARNING 1. • Use this unit only in the manner intended by this manual. If you have questions, contact ZLINE at 614-777-5004. • Before servicing or cleaning unit, switch power off at the service panel and disconnect the unit.
BEFORE INSTALLATION ALPINE UNDER CABINET MODELS BEFORE INSTALLATION ALPINE UNDER CABINET MODELS .7”/41” WARNING 34 28.4”/ NOTICE: Considering excessive weight, two or more people are required to install or move this appliance. Failure to do so can cause physical injuries. 8” GROUNDING INSTRUCTIONS 10” 12 ” 15amp, 120V, 60Hz This appliance must be grounded. The range hood is equipped with a cord having a grounding wire with a grounding plug.
BEFORE INSTALLATION ALPINE UNDER CABINET MODELS INSTALLATION ALPINE UNDER CABINET MODELS STEP 1: PROTECT THE COOKTOP Roof cap Put a thick, protective covering over counter top, cook top, or range to protect it from damage or dirt. Duct (for vertical discharge) STEP 2: CREATE WORK STATION (OPTIONAL) Ply wood or solid flatform Wood block approx 2.” thick Duct (for horizontal discharge) Cabinet Wall cap House wiring Hood 24”-30” (Electric hob) 30”-32” (Gas hob) 1.
Ply wood on solid flatform INSTALLATION ALPINE UNDER CABINET MODELS 8” metal duct INSTALLATION ALPINE UNDER CABINET MODELS 8” metal duct 15A, 120V, single outlet STEP 4: ATTACH 2” WIDE WOOD FILLER STRIPS Bottom cabinet 2” wide 2” wide 2” wide 15A, 120V, single outlet STEP 7: SECURE THE HOOD TO BOTTOM CABINET B Bottom cabinet Bottom cabinet 2” wide Flush with the front frame of cabinet Flush with Ply wood on Cabinet jackthe front frame of cabinet Ply wood on Cabinet jack Flush with the front fram
INSTALLATION ALPINE UNDER CABINET MODELS OPERATION ALPINE UNDER CABINET MODELS STEP 9: INSTALL OIL TUNNEL OR Grease cup (NOT AVAILABLE FOR ALL MODELS) • Power: Turn ON/OFF the range hood and activate power-off delay timer Oil tunnelOil tunnel Side viewSide view (3mins). Light Low Mid Stop • Low Speed: Light frying/boiling. High Light Mid High Stop Low Drop oil tunnel into recess support near rear of hood. Refer to the image above. • Medium Speed: Frying/wok cooking/heavy boiling.
MAINTENANCE AND CLEANING ALPINE UNDER CABINET MODELS HOW TO CHANGE OR REPLACE LIGHT BULB MAINTENANCE AND CLEANING ALPINE UNDER CABINET MODELS • If hood looks splotchy, use a stainless steel cleaner to clean the surface of 1. Make sure the range hood is unplugged or turn OFF breaker. the hood. Avoid getting cleaning solution on or into the control panel. Follow 2. Slightly press inward on the bulb using both thumbs. directions of the stainless steel cleaner. CAUTION: Do NOT leave on too long 3.
TROUBLESHOOTING ALPINE UNDER CABINET MODELS ZLINE Customer Service is available at 1-614-777-5004. FAULT Range hood does not operate after installation Range hood vibrates when the blower is on The blowers seems weak Alpine Under Cabinet Troubleshooting The lights work, but the blower is not spinning at all, is stuck, or is rattling. 33 TROUBLESHOOTING Check if the range hood has been plugged in. Make sure that all power has been turned back on and all electrical wiring is properly connected.
Installation Guide and User Manual 1.1.0 1-614-777-5004 contact@zlinekitchen.com www.zlinekitchen.