User Manual
10
The appliance shall be connected to a single phase electric line rated at 110-120Vac
and 60Hz frequency. The true voltage in most homes is usually between these values.
Electric Power Rating
220/240 Vac: 12A Max
If voltage is less than 220/240, then preheat times may vary.
Heating Element Power Rating
Electric Model:
Oven Bake (Electric): 1500 Watts
Oven Broil (Electric): 2850 Watts
Oven Circ. Element: 3200 Watts
Install suitable electric power supply receptacle connection type NEMA 14-50R able
to support a load of at least 30 A (Per Line) according to local code requirements.
For four wires power supply connection system (see diagram below).
Electrical Grounding
Our oven is equipped with a four-prong plug for your protection against shock
hazard and should be plugged directly into a properly grounded receptacle. Do not
cut or remove the prong from this plug.
Power Rating & Electrical Connection
L2 (red)
N (white)
G (green)
L1 (black)
L2 (red)
N (white)
G (green)
L1 (black)
cable from
power supply
Four-Wire Connection
Receptacle
NEMA 14-50R
Disconnect electrical power at the circuit breaker box or fuse box
before installing the appliance.
Provide appropriate ground for the appliance. Use copper
conductors only.
WARNING