Installation Guide and Users Manual
5 6
This appliance shall only be installed by an authorized professional. 
The appliance shall be installed in accordance with the standards of the country 
where it will be installed. The installation of this appliance must conform to local 
codes and ordinances. In the absence of local codes installation must conform to 
American National Standards, National fuel Gas code ANSI Z223.1-Latest edition/
NFPA 54 or B 149.1.
The appliance, when installed, must be electrically grounded in accordance with 
local codes or, in the absence of local codes, with the National Electrical code, 
ANSI/NFPA 70.
If local codes permit, a flexible metal appliance con-nections with the new AGA 
or CGA certified design, max 5 feet (1,5m) long, 34˝ I.D. is recommended for 
connecting this appliance to the gas supply line. DO NOT bend or damage the 
flexible connector when moving the appliance. 
This appliance must be used with the pressure regulator provided. The regulator must 
be properly installed in order to be accessible when the appliance is installed in 
its final location. The pressure regulator must be set for the type of gas to be used. 
The pressure regulator has 34˝ female pipe thread. The appropriate fitting must be 
determined based on the size of your gas supply line, the flexible metal connector 
and the shut-off valve. 
The appliance must be isolated from the gas supply piping system by closing its 
individual manual shut-off valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 34 PSI(13,8w.cpr 3,5kPA). 
All opening holes in the wall and floor, back and under the appliance shall be sealed 
before installation of the appliance. 
A manual valve shall be installed in an accessible location in the gas line external to 
the appliance for the purpose of turning on and shutting off the gas to the appliance.
Before Installation
Do not use aerosol sprays in the vicinity of this appliance while it is 
in operation. 
WARNING
Room Ventilation
An exhaust fan may be used with the appliance; in each case it shall be installed 
in conformity with the appropriate national and local standards. Exhaust hood 
operation may affect other vented appliances; in each case it shall be installed in 
conformity with the appropriate national and local standards.
Type of Gas
This appliance is shipped from the factory for use with natural gas. For use with 
propane LP gas, please follow the conversion procedure described on pg. 18. A step 
by step conversion procedure is also included with each set of LP gas nozzles.
Gas Pressure
The maximum inlet gas supply pressure incoming to the gas appliance pressure 
regulator is 34PSI (13,8w. cpr 3,5kPA). 
The minimum gas supply pressure for checking the regulator setting shall be at least 
1˝ w.c (249 Pa) above the inlet specified manifold pressure to the ap-pliance (This 
operating pressure is 4˝ w.c. (1.00kPa) for Natural gas and 11˝ w.c. (2.75 kPa) for 
LP gas.
Before Installation
Gas cooktop requires 1”- 6”side wall spacing above the counter height for 
proper combustion. Please review specific model installation instructions for 
required dimensions. 30 inches between the cooktop and bottom of the cabinet 
above. 0.25 inches for sides below countertop height. 
NOTE: Please consult your local building codes for variations with installation.