Installation Guide

WARNING!
Pressure Test Point Stopper Valve
To avoid gas leaks, the pressure test-point stopper
valve and gasket supplied with the range must be
installed on the gas tting at the back of the range
according to the diagram below.
Pressure Regulator
Since service pressure may uctuate with local de-
mand, every gas cooking appliance must be equipped
with a pressure regulator on the incoming service
line for safe and ecient operation.
Pressure Regulator
e pressure regulator shipped with the appliance
has two female threads 34”NPT. e regulator shall
be installed properly in order to the accessible when
the appliance is installed in its nal position.
Manifold pressure should be checked with a manom-
eter and comply with the values indicated below.
Natural Gas->430”W.c.P
LP/Propane-> 10.0” W.c.P
Incoming line pressure upstream from the regulator
must be 1˝ W.c.P. higher than the manifold pressure
in order to check the regulator.
e regulator used on this range can withstand a
maximum input pressure of ½ PSI (13.8˝ W.c or
3.5kPa) If the line pressure exceeds that amount, a
step down regulator is required.
e appliance, its individual shut-o valve, and the
pressure regulator must be disconnected from the gas
line during nay pressure testing of that system at pres-
sures in excess of 1/2PSI (13.8˝ W.c or3.5kPa).
Appliance Servicing
Before carrying out any service disconnect, the appli-
ance from gas appliance from nal to install have ac-
cess to the appliance for proper servicing intervention.
GAS CONVERSION
Before carrying out this operation,
disconnect the appliance from
gas and electricity.
Gas conversion shall be conducted
by a factory-trained professional.
Call customer service hot-line to
identify a factory-trained professional
near your home.
13