Installation Guide

ATTENTION: the range CANNOT be installed
directly adjacent to kitchen walls, tall cabinets, tall
appliances, or other vertical surfaces above 36˝
(91.4cm) high. The minimum side clearance is such
cases in 6” (15.2cm).
Wall cabinets with minimum side clearance must be
installed 30˝ above the countertop with coun-tertop
height between 35˝1/2 (90.2cm) and 37˝¼ (94.6cm).
The maximum depth of wall cabinets above the range
shall be 13˝ (33 cm).
Consider the critical dimensions of the appliance,
before making an opening in the top surface of the
bench top. (relative measurements
as per Fig. 1- 2).
A properly grounded and horizontally-mounted
electrical receptacle Type NEMA 14-50R should be
installed no higher than 3˝ (7.6cm) above the floor,
no less than
2˝ (5 cm) and not more than 8˝ (20.3cm)
from the left side (facing product); refer to Electrical
connection section page 10. Check all lo-cal code
requirements.
Gas
An agency-approved, properly-sized manual shut-
off valve should be installed no higher than 3˝
(7.6cm) above the floor and no less than 2˝ (5cm)
and no more than 8
˝ (20.3cm) from the right side
(facing product).
To connect gas between shut-off valve and regulator,
use agency-approved, properly-sized flexible or rigid
pipe. Check all local code requirements.
Installation Requirements Electrical
6