WARNING!
Pressure Test Point Stopper Valve
To avoid gas leaks, the pressure test-point stopper 
valve and gasket supplied with the range must be 
installed on the gas tting at the back of the range 
according to the diagram below. 
Pressure Regulator 
Since service pressure may uctuate with local de-
mand, every gas cooking appliance must be equipped 
with a pressure regulator on the incoming service 
line for safe and ecient operation. 
Pressure Regulator
e pressure regulator shipped with the appliance 
has two female threads 34”NPT. e regulator shall 
be installed properly in order to the accessible when 
the appliance is installed in its nal position. 
Manifold pressure should be checked with a manom-
eter and comply with the values indicated below. 
• Natural Gas->430”W.c.P
• LP/Propane-> 10.0” W.c.P
Incoming line pressure upstream from the regulator 
must be 1˝ W.c.P. higher than the manifold pressure 
in order to check the regulator. 
e regulator used on this range can withstand a 
maximum input pressure of ½ PSI (13.8˝ W.c or 
3.5kPa) If the line pressure exceeds that amount, a 
step down regulator is required. 
e appliance, its individual shut-o valve, and the 
pressure regulator must be disconnected from the gas 
line during nay pressure testing of that system at pres-
sures in excess of 1/2PSI (13.8˝ W.c or3.5kPa).
Appliance Servicing
Before carrying out any service disconnect, the appli-
ance from gas appliance from nal to install have ac-
cess to the appliance for proper servicing intervention. 
GAS CONVERSION
Before carrying out this operation, 
disconnect the appliance from 
gas and electricity. 
Gas conversion shall be conducted 
by a factory-trained professional.
Call customer service hot-line to 
identify a factory-trained professional 
near your home.