Installation Guide
WARNING!
A manual valve shall be installed in an accessible lo-
cation in the gas line external to the appliance for 
the purpose of 
turning on and shutting off the gas 
to the appliance. 
Do not use aerosol sprays in the vicinity of this 
appliance while it is in operation. 
Room Ventilation:  An  exhaust  fan may  be  used with 
the appliance; in each case 
it shall be installed in 
conformity  with  the  appropriate  national  and  local 
standards.  Exhaust  hood  operation  may  affect  other 
vented appliances; in each case it shall be installed in 
conformity  with  the  appropriate  national  and  local 
standards. 
Type of Gas
This appliance is shipped from the factory for use with 
natural gas. For use with propane LP gas please follow 
the conversion procedure described on pg. 14. A step 
by  step  conversion  procedure  is  also  included  with 
each set of LP gas nozzles. 
Gas Pressure
The maximum inlet gas supply pressure incoming to 
the  gas  appliance  pressure  regulator  is  34PSI  (13,8w. 
cpr 3,5kPA). 
The  minimum  gas supply pressure for checking the 
regulator setting shall be at least 1˝ w.c (249 Pa) above 
the inlet specified manifold pressure to the ap-pliance 
(This  operating  pressure  is  4˝  w.c.  (1.00kPa)  for 
Natural gas and 11˝ w.c. (2.75 kPa) for LP gas.
Before Installation
This appliance shall only be installed by an autho-
rized professional. 
The appliance shall be installed in accordance with 
the standards of the country where it will be in-
stalled. The installation of this appliance must con-
form to local codes and ordinances. In the absence of 
local codes installation must conform to American 
National Standards, National fuel Gas code  ANSI 
Z223.1-Latest edition/NFPA 54 or B 149.1.
The appliance, when installed, must be electrically 
grounded in accordance with local codes or, in the 
absence of local codes, with the National Electrical 
code, ANSI/NFPA 70.
If local codes permit, a flexible metal appliance con-
nections with the new AGA or CGA certified design, 
max 5 feet (1,5m) long, 34˝ I.D. is recommended for 
connections this appliance 
to the gas supply line. DO 
NOT bend  or damage the flexible  connector when 
moving the appliance. 
This appliance must be used with the pressure reg-
ulator provided. The regulator must be properly in-
stalled in order to be accessible when the appliance is 
installed in its final location. The pressure regulator 
must be set for the type of gas to be used. The pres-
sure regulator has 34˝ female pipe thread. The appro-
priate fitting must be determined based on the size of 
your gas supply line, the flexible metal connector and 
the shut-off valve. 
The appliance must be isolated from the gas supply 
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 34 
PSI(13,8w.cpr 3,5kPA). 
All opening holes in the wall and floor, back and 
under the appliance shall be sealed before installa-
tion of the appliance. 
5