Installation Guide
ATTENTION: the  range  CANNOT  be  installed 
directly  adjacent  to  kitchen  walls,  tall  cabinets,  tall 
appliances,  or  other  vertical  surfaces  above  36˝ 
(91.4cm) high.  The  minimum side  clearance is  such 
cases in 6” (15.2cm). 
Wall cabinets with  minimum  side  clearance must be 
installed  30˝ above  the  countertop  with  coun-tertop 
height between 35˝1/2 (90.2cm) and 37˝¼ (94.6cm). 
The maximum depth of wall cabinets above the range 
shall be 13˝ (33 cm).
Consider the critical dimensions of the appliance, 
before making an opening in the top surface of the 
bench top. (relative measurements
as per Fig. 1- 2).
A properly grounded and horizontally-mounted 
electrical receptacle  Type NEMA 14-50R should be 
installed no higher than 3˝ (7.6cm) above the floor, 
no less than 
2˝ (5 cm) and not more than 8˝ (20.3cm) 
from the left side (facing product); refer to Electrical 
connection  section  page  10.  Check  all  lo-cal  code 
requirements.
Gas
An agency-approved, properly-sized manual shut-
off valve should be installed no higher than 3˝ 
(7.6cm) above the floor and no less than 2˝ (5cm) 
and no more than 8
˝ (20.3cm) from the right side 
(facing product). 
To connect gas between shut-off valve and regulator, 
use agency-approved, properly-sized flexible or rigid 
pipe. Check all local code requirements.
Installation Requirements Electrical
6