User's Manual Part 2

Page 22
English
Problem Cause Solution
The ashing indicator lights
(9300/P93) or error code
on the display (9400/P94,
9500/P95) appear just after
start (either pressing Power
or Cycle button for less than
20 seconds).
NOTE: If the ashing lights
are accompanied by an
error code on the display,
refer to section 8.4 Control
Unit Error Codes.
Floating cable may not be plugged
into the control unit correctly.
Unplug oating cable from the control unit and
reconnect.
Cleaner may not be fully submerged. Remove cleaner from the pool and re-submerge, see
Submerging the Cleaner.
Cleaner may need to be reset and
begin a new cycle.
Press power button OFF, then Cycle I or Cycle II to
begin a new cycle.
Propellor may be jammed and not
turning correctly.
Contact Polaris Technical Support at (USA)
1-800-822-7933.
Wheels may be jammed and not turn-
ing correctly.
Contact Polaris Technical Support at (USA)
1-800-822-7933.
The ashing lights appear
during the cleaning cycle.
Cleaner may be sucking air (lights will
appear after 60 seconds air intake)
Remove cleaner from the pool and re-submerge, see
Submerging the Cleaner.
The cleaner does not stay
rmly on the pool bottom.
There is air in the appliance casing. Submerge the cleaner following the procedure in
Submerging the Cleaner.
The lter canister is full or dirty. Clean the lter canister, see Cleaning the Filter
Canister.
The cleaner does not or no
longer climbs the pool sides.
The lter canister is full or dirty. Clean the lter canister, see Cleaning the Filter
Canister.
Sides of pool are slippery or slimy.
Although the water seems clear,
microscopic algae, invisible to the
human eye, are present in the pool.
As a result the pool sides become
slippery and prevent the cleaner from
climbing. Check tires for wear and
replace as necessary.
Do a shock chlorination treatment and slightly reduce
the pH. DO NOT leave the cleaner in the pool during
this treatment.
On startup the cleaner does
not move.
Not supplied with electricity. The outlet, the control unit is connected to, is not
supplying electrical power. Check that the outlet
to which the control unit is connected is receiving
electricity.
Unit is turned ON. Check that you have started one (1) of the two (2)
programs and check that the indicator for the selected
program is lit. If the indicator light is not lit, turn the
wheels then disconnect the control unit and wait at
least 20 seconds before reconnecting. If the problem
persists, contact Polaris Technical Support at (USA)
1-800-822-7933.
Cable is tangling in the pool Too much cable length in the water. Do not unravel the entire cable length.
Place only the required length of cable in the water
and place the rest on the side of the pool.
Follow the procedure in Cord Tangling to avoid and
correct tangled cord.
The cleaner is not cleaning
effectively.
The brushes have become smooth or
the "wear" indicator shows.
Replace the brushes following the procedure in
Replacing the Brushes.
Filter canister is full or dirty. Clean the lter canister following the procedure in
Cleaning the Filter Canister.
Floating cable is excessively coiled or
kinked.
Make sure the oating cable is spread out over the
pool. Ensure the cable is not too tightly wrapped or
coiled when storing. If the problem persists, lay the
cable straight in the sun to relax it and remove kinks.
8.3 General Troubleshooting
The following table lists some of the more common symptoms, causes and solutions encountered when using the
9400Sport/P94andthe9500Sport/P95cleaner.