2.2 Malfunctions of the appliance
2.2.1 The appliance does not work
Causes Verification / solution
No display Check the supply voltage and the fuse
The pool temperature is above the temperature
setpoint.
Increase the temperature setpoint.
A message is on the screen. Check the meaning of message §2.1
2.2.2 The appliance operates but the water temperature does not rise
Causes Verification / solution
Not enough filtering time
Put the filtering on manual 24/24 hours to raise
the temperature.
Non-complying period of use
Check whether the heat pump is of the right
dimension for this period of the year.
The heat pump is under-dimensioned.
Check the characteristics of the heat pump
according to the pool.
The automatic pool water filler is jammed in open
position.
Checking correct operation of the automatic filler.
The heat insulating cover is not used. Put on the heat insulating cover.
The evaporator is fouled. Clean the evaporator (see §3.1)
The appliance is badly installed.
The appliance must be installed outdoors.
Make sure there is no obstacle less than 4
metres from where the blower is facing, and 0.50
metre behind the heat pump.
2.2.3 The fan turns but the compressor stops from time to time without an error
message appearing
Causes Verification / solution
The heat pump does defrosting cycles from time to
time.
Normal if the outside temperature is lower than
12 °C.
The evaporator is fouled. Clean the evaporator.
2.2.4 The heat pump trips out or attempts to start itself from time to time
Causes Verification / solution
The circuit breaker is under dimensioned or badly
dimensioned.
Check the circuit breaker (see § 1.4.5.1).
The cable section is to small. Check the cable section (see §1.4.5.3)
The supply voltage is to low. Call your electricity board.