Temperatures for information
1.2 Technical characteristics
PF
Single
phase
voltage
Power
consumed*
Power
restored*
Nominale
current
consumption*
COP*
Sound
power*
Sound
pressure at
10 meters*
Weight
kW kW A dBA dBA Kg
6M
230V-50Hz 1.35 6.6 6.25 4.9 65.3 37.3 51
8M
230V-50Hz 1.59 7.8 7.3 4.9 65.2 37.2 52
11M
230V-50Hz 2.20 11 10.5 5 66.7 38.7 63
13M
230V-50Hz 2.83 13.3 13 4.7 65.1 37.1 68
15M
230V-50Hz 3.10 15.5 15 5 65.1 37.1 81
* with an ambient air of +15 °C and a pool water of 24 °C, humidity 70%
unit protection class: IP 24
refrigerant gas: R410A
refrigerant charge: see product name plate
class : I,
degree of pollution : 2,
overvoltage category : II
Exclusive use: heating swimming pool water