Unit installation
4
1.3 Operating conditions
Operating range:
between 5 °C and 38 °C of air temperature
between 5 °C and 32 °C of water temperature
1.4 Installation
1.4.1 Access to technical compartment
1.4.2 Selection of installation site
the heat pump must be installed:
- at a minimum distance from the end of the pool, as defined by the applicable
national electrical standards. In France, the NF C 15 100 standard (section 702)
specifies that this device must be installed more than 2 meters from any basin or
water reserve. In case it may be subjected to water jets, provide for a minimum
distance of 3.5 meters.
the heat pump must not be installed:
- near a source of heat or inflammable gas,
- near a road with the risk of water and mud splashes,
- facing a strong wind,
- with the blowing towards a window or nearby wall,
- with the blowing less than 4 metres from a permanent or temporary obstacle.
Keep the appliance out of the reach of children.
Any bad installation can cause serious material or bodily damage (and can cause
death).
The appliance must be installed outdoors and must be surrounded by free space
(see §1.4.4).
The installation and the hydraulic and electrical connections must be done to
standards in force and especially standard NF C 15 100 for France (equivalent to
EC I 364).
Do not pick up the unit by the outside case, use the base to lift the unit.
Maximum temperature limited at 32°C to protect the pool liner.
EN