“Priority heating” wiring and operating diagram:
A1-A2: supply to power contactor coil of the filtering pump
filter timer
power contactor (3-pole or 2-pole), supplying the filter pump
connection cable, wire gauge 2 x 1.5 mm² minimum (service voltage 300Vac)
controller board with “priority heating” output, terminals 16-17
heat pump B1 regulation electronic card (see placing § “dimensions and description” in the appendix)
Never power the filter pump motor directly through terminals 16-17 located on plate
.
Terminals 16-17 may remain live even if the heat pump is disconnected from the
power source.
Before performing any work on the machine, cut off the power to the filter timer at
its circuit breaker (F on the diagram above).
Incorrect connection of terminals 16-17 may damage the regulator and renders the
warranty invalid.
The minimum wire gauge for connection of the priority heating function is: 2x1.5
mm², of type RO2V or equivalent in countries outside the European Community, and
with an outer diameter between 8 and 13 mm.
Remove the plug (upper the cable gland) and fit the cable gland for passage of the
cable into the unit.
Once the cable is inserted in this stuffing box, block it by pulling lightly on the cable
to retract it one centimeter.