PW 5M-7M-9M-11M Instructions for installation and use English More documents on: www.zodiac-poolcare.com H0357900.
• Read this notice carefully before installing, maintaining or repairing this appliance! indicates important information that you must take into account to avoid the risk • The symbol of damage to persons or the appliance. • The symbol indicates useful information as an indication. Warning • As part of a continuous improvement process our products may be modified without prior notice.
Contents 1. Information before installing................................................................................................................... 3 1.1 General delivery terms and conditions ...................................................................................................... 3 1.2 Content............................................................................................................................................................ 3 1.3 Technical specifications .......
1. Information before installing 1.1 General delivery terms and conditions All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The latter must make written reserves on the transporter’s delivery documents if damage during transport is discovered (confirmed by registered letter to the transporter within 48 hours). If the appliance has been tipped over, make written reserves to the transporter. 1.
2.3 Hydraulic connections VE: water intake valve VB: by-pass valve VS: water output valve * minimum distance PW 5M Test pressure bar Service pressure bar Load loss mCE 1 Water flow optimum m³/h 4 minimum Water flow m³/h maximum* * rate not to be exceeded 7M 9M 6 1.5 1 1.5 6 8 11M 1.5 8 10 Follow the hydraulic connection direction (see § «Sizes» in the appendix). • • The connection will use Ø40 piping, or Ø50 using the supplied adapter (see §1.
• • • • • Loose terminals can cause the terminal block to heat and lead to the warranty being voided. It is imperative to connect the appliance to an earth rod. Risk of electric shocks inside the appliance. Only a qualified and experienced technician is authorised to wire inside the appliance. If the power supply cable is damaged it should be replaced by a qualified technician. 2.4.
• Possibility of reading the water temperature: when water is flowing through the heat pump, press : flashes 10 seconds then the fixed temperature set point is displayed, Possibility of locking the keyboard: • - Keyboard lock: press and at the same time for 3 seconds: appears for 3 seconds, then: , - Unlocking the keyboard: press then: and at the same time for 3 seconds: flashes for 4 seconds, . 3.
• During the maintenance phase make sure there are no traces of corrosion or oil stains around the refrigerating components. Before any operations on the refrigerating circuit it is imperative to shut down the appliance and to wait a few minutes before fitting temperature or pressure sensors. Some equipment such as the compressor and piping can reach temperatures in excess of 100°C and high pressures which can cause serious burns. • 4.2.
Malfunction The appliance is working but the water temperature does not rise • • • • • • • • Possible causes Insufficient filtering time Usage period not compliant The heat pump is undersized The automatic pool filling is blocked in the open position The heat insulated cover is not used The evaporator is dirty The appliance is incorrectly located There is a message on the screen • • • • • • • • • The heat pump is tripping the circuit breaker • • • The circuit breaker is incorrectly or wrongly sized The
Electric diagram PW 5M-7M-9M P1 Power supply 230V-1N-50Hz 1 PW 11M L-N-PE H0357900.
AF Digital display KM2 Fan relay Earth KM3 Auxiliary pump relay C1 C2 C3 CD Compressor capacitor Fan capacitor Auxiliary pump capacitor Flow rate controller KM4 M1 M2 M3 Complementary relay Compressor Fan Auxiliary pump E1 High pressure switch P2 Auxiliary pump connector E2 ED1 F1 KM1 Low pressure switch Auxiliary pump Fuse Compressor relay SD1 SD2 SD3 T1 Water temperature sensor Air temperature sensor Defrost sensor Transformer Dimensions PW 5M 7M 9M 11M Weight (Kg) 45 47 48 51 Descri
Zodiac Pool Care Europe - BP 90023 - 49180 St Barthélémy d’Anjou cedex - S.A.S.U. au capital de 517 200 € / SIREN 395 068 679 / RCS PARIS www.zodiac-poolcare.com Pour plus de renseignements, merci de contacter votre revendeur. For further information, please contact your retailer. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.