Install Instructions
© Copyright 2012 Zoeller Co. All rights reserved.
WARNING:
ELECTRICAL SHOCK
HAZARD
FAILURE TO DISCONNECT ALL
POWER BEFORE SERVICING
COULD RESULT IN INJURY OR DEATH.
LR54245
LISTED
288X
LOUISVILLE, KY
R
L
U
R
Figure G
SK2375
Connect the two conductors from the control switch to either of the terminations on the bottom of the alarm panel (see Fig. G).
The control switch operates on low voltage and is isolated from the 120 VAC power line to reduce shock hazards.
TEST
Check and test your installation by lifting the oat manually (see Fig. D or F). The alarm panel should indicate an alarm
condition. The Zoeller Company cannot be responsible for damages caused by faulty or negligent installation of this device.
We respectfully suggest you engage the services of a qualied licensed electrician or service person. Push TEST button
once per week to verify proper operation.
NOTE: Alarm systems 10-2613 and 10-2615 are not intended to be used in sewage holding tank systems.
VERTICAL REED FLOAT SWITCH
(10-2613, 10-2615)
DO NOT install switch in direct line of incoming liquid.
1) Place the clamp into the switch housing as shown. (see Fig. E).
2) Locate clamp at desired activation level and secure the clamp to the discharge pipe as shown (see Fig. E).
NOTE: DO NOT install cord under hose clamp.
3) Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the switch housing.
4) Check installation. Allow system to cycle to insure proper operation.
NOTE: When installing the control switch, a cable strain relief must be used to secure the control switch cord.
SK1301F
SK1301G
Figure E Figure F
CONTROL SWITCH INSTALLATION
CONTROL SWITCH WIRING